Programming Sequences 

The programming information on the following pages explains 
the programming options.  The telephone is shipped from the 
factory with a set of default parameters that are listed in the 
Programming Table on page 29.  A “User Settings” section has 
been provided in the Programming Table for the user to record 
the selected programming parameters. 

Dialing Options 

The auto-dial telephones can be configured for either auto-dialing or ring-down operation.  Select the 
dialing option that fits your application.  The dialing options are explained in detail below. 

Auto-dialing 

The 

CALL

 push button can be programmed to call up to three unique telephone numbers.  The unique 

telephone numbers include a primary telephone number and two backup, or roll over, numbers.  In the 
event an auto-dial call cannot connect to the primary telephone number (i.e., a busy signal or no answer), 
the auto-dial telephone will automatically dial the first backup, or roll over, number.  Again, in the event 
an auto-dial call cannot connect to first back-up telephone number, the auto-dial telephone will 
automatically dial the second backup, or roll over, number (if used).  This sequence will continue until the 
auto-dial call is answered, or all numbers have been attempted (one attempt each). 

When operating in SMART mode, the number of attempts to call each programmed number can be 
increased, as required, (two attempts each, three attempts each, etc.) 

For the rollover feature to function properly in this mode, all three auto-dial memories must be 
programmed with valid telephone numbers.  The three auto-dial numbers can be the same or any 
combination of telephone numbers.  If the telephone is programmed with only one or two auto-dial 
numbers, the rollover operation will not function and the numbers will only be dialed one time. 

If an auto-dial telephone is connected to a PBX, PABX, KSU, etc., telephone system, the auto-dial 
telephone can be programmed to access outside CO lines.  Typically access to a CO line requires adding a 
digit (e.g., 9) to the auto-dial number.  Also, a “pause” may be required in the auto-dial number.  The 
pause typically is required to wait for secondary (CO line) dial tone.  See the example in the Call Button 
Auto-dial Number 1 on page 23. 

In addition to the pause, the auto-dial telephone has a programmable Primary Dial Tone Delay and 
Secondary Dial Tone Delay.  Both delays determine the amount of time the auto-dial telephone will wait 
before dialing the stored telephone number.  The Secondary Dial Tone Delay can only be used if a “9” is 
dialed to gain access to a CO line. 

Programming Legend 

  D  = DTMF digit 0–9, *, or # 
  N  = Numeric digit 0–9 
  L  = 0 - Disable, 1 - Enable 

Содержание 393-001AD

Страница 1: ...a Call 4 Location Identification Code Dialing 4 Installation 5 Safety Guidelines 5 General Installation Guidelines 6 Security Hardware 6 Conduit Installation Details 6 Models 393 00xAD and 393AL 00xA...

Страница 2: ...ramming Sequence 21 Password Disabled Programming 21 Programming Sequences 22 Dialing Options 22 Password Protection 24 Auto Answer Alert Feature 24 Disconnect Options 25 Americans with Disabilities A...

Страница 3: ...ne in a non emergency environment Each AD series telephone complies with the Americans with Disabilities Act ADA in both physical and operational characteristics Each telephone includes a Braille labe...

Страница 4: ...AD Surface Mount Telephone single auto dial push button weatherproof glass reinforced polyester enclosure safety yellow 393 003AD Surface Mount Telephone single auto dial push button weatherproof glas...

Страница 5: ...nderstanding that if two or more telephones are put into use simultaneously the line current could drop sufficiently to disconnect the telephone call completely This will depend on the line current th...

Страница 6: ...de the following Remote disconnect of a call Called party transmits either a or 99 DTMF control command Manual disconnect of a call Press the CALL push button approximately 15 seconds after the initia...

Страница 7: ...al Electrical Code NEC Grounding has to be ensured for safe and stable communications Do not use long and coiled ground wires Trim ground wires to the required length Use a star configuration whenever...

Страница 8: ...epend on the line current the length of the cable run and the condition of the telephone cable NOTE A RED ALERT Telephone should never be installed on the same telephone line as any other non RED ALER...

Страница 9: ...or the recommended conduit installation details Figure 1 Bottom entry conduit recommended for non metallic enclosures Figure 2 Top entry conduit installation for non metallic enclosures NOT recommende...

Страница 10: ...conduit entries 1 Pull the telephone line through the conduit and into the enclosure Connect the telephone line to the customer supplied telephone line surge suppressor if applicable and modular jack...

Страница 11: ...4 472B AUTO DIAL TELEPHONE MANUAL PAGE 9 of 33 f standard ioms current release 42004 instr manuals 42004 472b doc 01 15 Figure 6 Model 393AL 001AD Figure 7 Model 393 00xAD and 393AL 00xAD Component Lo...

Страница 12: ...Figure 9 cutout dimensions NOTE If mounted outdoors the installation of a telephone line suppressor customer supplied on the telephone line is recommended Figure 8 Model 397 00xAD 3 Remove the tapered...

Страница 13: ...nds to initialize 7 Using the Setup section of this manual Configure the hardware as required Refer to the Hardware Configuration section on page 14 for details Adjust the audio levels if necessary Re...

Страница 14: ...PUB 42004 472B AUTO DIAL TELEPHONE MANUAL PAGE 12 of 33 f standard ioms current release 42004 instr manuals 42004 472b doc 01 15 Figure 9 Model 397 00xAD Mounting Details...

Страница 15: ...lephone PCBA Remove the jumper from P17 pins 3 and 4 and insert to the adjacent header J18 when using the plug in power supply See Figure 11 on page 16 for jumper locations NOTE The external power sup...

Страница 16: ...n Enable J14 jumper in position EN Disable J14 jumper in position DIS Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled to allow...

Страница 17: ...osition STD Low PowerModeConfiguration Factory Setting Low Power Mode Disabled For some installations in which only minimal loop current is available the performance of the telephone may be improved b...

Страница 18: ...d solid state switches capable of switching a maximum of 48 V dc 125 mA or 28 VRMS ac 80RMS mA TB2 OUT1 and TB5 OUT4 on the auto dial telephone PCBA provides the connections for the auxiliary outputs...

Страница 19: ...e power supply is a connectorized 4 foot power cable that plugs into P17 on the telephone PCBA P17 must be vacated prior to plugging in the power supply To do so remove the jumper from P17 pins 3 and...

Страница 20: ...a GAI Tronics 530 Series Strobe NOTE Output 1 can be programmed to remain closed for up to 255 minutes in 1 minute increments after the auto dial call ends This output extension can be deactivated vi...

Страница 21: ...lose for a pre programmed amount of time then release The RED ALERT Telephone will acknowledge acceptance of this deactivation command with a short beep If the beep is not initially received retry the...

Страница 22: ...n Each RED ALERT Telephone is factory programmed to receive Standard Mode commands Factory default settings are shown in Table 11 on page 29 Set up Sequence Set up each RED ALERT Auto Dial Telephone f...

Страница 23: ...seconds elapses between digit entries or if an invalid password is entered 2 If DTMF digits have not been dialed within 3 seconds of the first success tone the telephone will exit programming mode and...

Страница 24: ...equence will continue until the auto dial call is answered or all numbers have been attempted one attempt each When operating in SMART mode the number of attempts to call each programmed number can be...

Страница 25: ...al Number 2 DD 2 Same as CALL Button Auto dial Number 1 except the sequence ends in 2 instead of 1 None CALL Button Auto dial Number 3 DD 3 Same as CALL Button Auto dial Number 1 except the sequence e...

Страница 26: ...ramming Feature Key Sequence Description Default Password Protection 1 4 N N N N A four digit password must be supplied to remotely program the telephone If you change the password and cannot enter pr...

Страница 27: ...out Disconnect Option 1 2 N N This feature programs the maximum length of a call if no other disconnect features are used The valid entries are 1 99 representing 1 minute increments and 0 representin...

Страница 28: ...les and stores the three digit location identification ID number To enable the ID feature set L 1 To disable the ID feature L 0 Enter the three digit location identification code in the sequence N N N...

Страница 29: ...ut 4 can be set in the range of 0 1 to 12 7 seconds in 0 1 second increments Table 9 Output 4 Control Options Feature Key Sequence Description Default Control Sequence N N 8 Assigns the digits NN as t...

Страница 30: ...cally within less than 1 second after the unit completes the dialing sequence Use of the Early Microphone feature includes an operational risk that ring back tones can be missed or audio received by t...

Страница 31: ...Protection Feature Programming see Table 4 on page 24 14NNNN 2468 Disconnect Options Programming see Table 6 on page 25 Emergency Push button Disconnect 17L 1 enabled Call Time out Disconnect 12NN 10...

Страница 32: ...e the USA for help identifying the Regional Service Center closest to you Preventive Maintenance for Flush Mount Telephones Stainless steel does not normally require maintenance to prevent corrosion f...

Страница 33: ...Operating temperature range 003AD Models 40 F to 140 F 40 C to 60 C 001AD Models 4 F to 140 F 20 C to 60 C Relative humidity to 95 no condensation Model 393 00xAD Enclosure construction Valox high imp...

Страница 34: ...0 Ringer Equivalence Number 5B Connection Method CA11A Replacement Parts Part No Description 393 001AD 393 003AD 393AL 001AD 393AL 003AD 397 001AD 397 003AD 233 001 Model 233 001 Security Screwdriver...

Страница 35: ...al telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degra...

Страница 36: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: