P
UB
.
42004-472B
A
UTO
-D
IAL
T
ELEPHONE
M
ANUAL
P
AGE
24 of 33
f:\standard ioms - current release\42004 instr. manuals\42004-472b.doc
01/15
Password Protection
The Password Protection feature allows you to change the four-digit password required to program the
auto-dial telephone. Each telephone is password protected to maintain the integrity of programmed
information and should not be disabled.
The password is required to enter the programming mode when programming the telephone locally or
from a remote location. The programming password hardware configuration must be enabled when
programming with the password. To enable the Password Protection feature,
J9
jumper must be in the
“EN” position. Complete the key sequence to change the four-digit password.
Table 4. Password Programming
Feature
Key
Sequence
Description
Default
Password
Protection
# 1 4
N N N N
A four-digit password must be supplied to remotely program
the telephone. If you change the password and cannot enter
programming mode, see the “Password Disabled Programming”
section.
Example
: To program the password
1234
, enter
#
1
4
1
2
3
4
.
2468
Auto-Answer Alert Feature
When auto-answering an incoming call, the RED ALERT
®
Telephone will generate a splash tone on the
telephone line. This tone is always heard by the calling party. This tone can be pre-programmed to also
be heard over the telephone’s integral speaker using this key sequence.
Table 5. Auto-Answer Alert Programming
Feature
Key
Sequence
Description
Default
Auto-answer
Alert
# 1 6
L
The Auto-Answer Alert feature allows a person to call the
emergency telephone and monitor the area around the telephone
with or without sounding a splash tone over the unit’s integral
speaker.
(Disable alert tone),
L
=0.
(Enable alert tone),
L
=1.
1