RED DSMC OPERATION GUIDE
COPYRIGHT © 2014 RED.COM, INC
955-0020_V5.1, REV-H
|
41
TC
TC Gray
: No analog time code is currently detected.
TC Red
: Analog time code is being detected, but the use of it is not enabled.
TC Green
: Analog time code is being used to jam the time of day time code. TC will revert to gray if the signal
is no longer detected.
GEN
GEN Gray
: No genlock signal is currently detected, or the presented signal cannot cross-lock to project
(24.00 FPS vs. 23.98 FPS).
GEN Red
: During process of sync, or genlock is lost while recording.
GEN Green
: A genlock signal matching the current HD-SDI monitor rate has been locked to.
GEN Yellow
: When timing is cross-locking to compatible but not matching monitor rate. For example, gen-
lock = 24.00, and HD-SDI monitor rate = 25.00.
NOTE:
3D operation should not be done if GEN is yellow. This is a warning that genlock source settings and
camera settings are not aligned. Phasing of the sync between cameras cannot be guaranteed when GEN is
yellow.
SYNC
SYNC Gray
: The sensor sync mode is not Genlock.
SYNC Red
: The sensor sync mode is Genlock, but it is not locked to any genlock signal, or genlock or sen-
sor sync is lost while recording.
SYNC Green
: A genlock signal compatible with the HD-SDI monitor rate has been locked to and the sensor
timing is also locked to it.
LAN
LAN Gray
: External control of the camera is not currently enabled.
LAN Yellow
: If the LAN icon is yellow, you will see the message “For reliable external control over Ethernet
your camera’s hardware may need to be upgraded. Please contact your Bomb Squad representative”. If you
see this message, you will not be able to control the camera externally. Please contact your Bomb Squad
representative to have your hardware upgraded.
POWER STATUS
If powering camera through DC power, the current voltage will be displayed. If using batteries, the remaining
battery time displays.
If using a RED BRICK or similar external battery to power the camera through DC IN, power status displays
the current supply voltage available from the battery. Supply voltage decreases as battery is discharged, the
displayed text is color coded as follows:
Green
: 12.0 V and up
Yellow
: 11.9 – 11.8 V
Red
: 1.7 – 11.6 V
NOTE:
The camera will automatically power down if supply voltage drops to 11.5 Volts.
If using a REDVOLT battery in the DSMC SIDE HANDLE or Battery Module to power the camera, power status
displays the location of the power source (example: SH: SIDE HANDLE; RM: Rear Module) and reports the re-
maining battery capacity and the displayed text is color coded as follows:
Green
: >10 minutes
Yellow
: 5-10 minutes
Red
: <5 minutes
If using a RED BRICK battery connected to DC IN, power status displays BRICK and reports the % of remaining
Содержание SCARLET-X
Страница 1: ...EPIC SCARLET V5 1 DRAGON MYSTERIUM X RED COM RED DSMC O PERAT ION GU IDE ...
Страница 154: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 1 REV H 154 SIDE VIEW ...
Страница 155: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 1 REV H 155 TOP VIEW ...
Страница 156: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 1 REV H 156 BOTTOM VIEW ...
Страница 157: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 1 REV H 157 BACK VIEW ...