red
PELLET STOVES
Chapter 4
INSTALLATION AND USE MANUAL
page
43
Operation
Technical service - Rights reserved - Reproduction prohibited
PROGRAMME 4 (7:30 a.m. - 10:30 p.m. Saturday and
Sunday)
DESCRIPTION
ACTIVATION
STEP
DISPLAY
CONFIRMATION
Programme 4: stove lighting time 7:30 a.m. (hot at 8:00 a.m.)
Button 1 or Button 2
UT 05
7 : 30
Button 3
Programme 4:
stove shutdown time 10:30 p.m. (cold at 11:00
p.m.)
Button 1 or Button 2
UT 06
22 :30
Button 3
Programme 4: inactive day Monday
Button 2
UT 07
ON 1 or OFF 1
Programme 4: inactive day Monday
Button 1
UT 07
OFF 1
Programme 4: inactive day Tuesday
Button 2
UT 07
ON 2 or OFF 2
Programme 4: inactive day Tuesday
Button 1
UT 07
OFF 2
Programme 4: inactive day Wednesday
Button 2
UT 07
ON 3 or OFF 3
Programme 4: inactive day Wednesday
Button 1
UT 07
OFF 3
Programme 4: inactive day Thursday
Button 2
UT 07
ON 4 or OFF 4
Programme 4: inactive day Thursday
Button 1
UT 07
OFF 4
Programme 4: inactive day Friday
Button 2
UT 07
ON 5 or OFF 5
Programme 4: inactive day Friday
Button 1
UT 07
OFF 5
Programme 4: Active day Saturday
Button 2
UT 07
ON 6 or OFF 6
Programme 4: Active day Saturday
Button 1
UT 07
ON 6
Programme 4: Active day Sunday
Button 2
UT 07
ON 7 or OFF 7
Programme 4: Active day Sunday
Button 1
UT 07
ON 7
Programme 4: CONFIRM
UT 08
Button 3
If a programme is not used, all days of the week relating to that programme must
be set to "OFF"
DESCRIPTION
ACTIVATION
STEP
DISPLAY
CONFIRMATION
Programme 4: stove lighting time - NOT USED
UT ..
ANY
Button 3
Programme 4: stove shutdown time - NOT USED
UT ..
ANY
Button 3
Programme 4: inactive day Monday
Button 2
UT ..
ON 1 or OFF 1
Programme 4: inactive day Monday
Button 1
UT ..
OFF 1
Programme 4: inactive day Tuesday
Button 2
UT ..
ON 2 or OFF 2
Programme 4: inactive day Tuesday
Button 1
UT ..
OFF 2
Programme 4: inactive day Wednesday
Button 2
UT ..
ON 3 or OFF 3
Programme 4: inactive day Wednesday
Button 1
UT ..
OFF 3
Programme 4: inactive day Thursday
Button 2
UT ..
ON 4 or OFF 4
Programme 4: inactive day Thursday
Button 1
UT ..
OFF 4
Programme 4: inactive day Friday
Button 2
UT ..
ON 5 or OFF 5
Programme 4: inactive day Friday
Button 1
UT ..
OFF 5
Programme 4: inactive day Saturday
Button 2
UT ..
ON 6 or OFF 6
Programme 4: inactive day Saturday
Button 1
UT ..
OFF 6
Programme 4: inactive day Sunday
Button 2
UT ..
ON 7 or OFF 7
Programme 4: inactive day Sunday
Button 1
UT ..
OFF 7
Programme 4: CONFIRM
UT ..
Button 3
4.11.
SAFETY DEVICES
The stove is fitted with the following safety devices:
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down
the pellet feed screw in the event of an obstructed flue or
significant back-pressure (from the wind).
SMOKE TEMPERATURE SENSOR
Monitors the temperature of the smoke, and gives permission for
startup or shuts the stove down when the smoke temperature falls
below the preset value.
CONTACT THERMOSTAT IN THE FUEL HOPPER (KLIXON)
If the temperature exceeds the preset safety level, it immediately
shuts down the running of the stove.
Содержание ORCHIDEA HYDRO
Страница 1: ...USE AND MAINTENANCE MANUAL...