4.6.
CONTROL OF WATER TEMPERATURE IN
BOILER
The stove is already set with a series of standard parameters that allow
it to operate properly (water temperature 65°C and ambient
temperature 22°C). However, the user can change these parameters in
the following way:
The following parameters can be set:
T Ambient
This is the temperature that you want to attain in the
room where the stove is installed. To adjust it, press
ONCE on the button
“SET” and change the
values using the buttons
or
T H
2
O
=
Maximum temperature of water in boiler. Upon reaching
this temperature, the stove will reduce its performance to
prevent overheating. The default temperature is 65°C
and it can not be set below 40°C or over 80°C.
To adjust it, press
TWICE in rapid succession on the
button
“SET” and change the values using the
buttons
or
It is not advisable to set the temperature below
50/55°C so as to prevent the formation of
condensation in the boiler
4.7.
FIRST LIGHTING
You are now ready to light your stove.
The following is a brief description of how to light and extinguish your
stove to satisfy your curiosity and expectations.
4.7.1.
Lighting the stove
To light the stove
from
the panel
, press the button
for a few
seconds.
After about 15 minutes, the display (8) will show the ambient
temperature on the upper display and the water temperature
in the boiler on the lower display. The stove is now LIT.
If you have completed the lighting phase and there is no flame (the
stove is not lit), the display
(8)
will show the message “
Alarm no
ignition
” accompanied by an intermittent sound alarm. In this case,
turn the stove off by pressing for a few seconds on the button
.
The display
(8)
will show the message “Off / current time".
Check the grate. Are there pellets?
If this is the first lighting, the fuel which has to
travel from the hopper to the grate is not arriving in
time or in the properly programmed amount. In this
case the grate will either be empty or will contain
very few pellets.
REMOVE ANY PELLETS FROM THE BURNER AND
REPEAT IGNITION BY PRESSING FOR A FEW
SECONDS ON THE BUTTON
.
System pressure temperature setting
Setting of ambient temperature
SET
TURBO
1
2
6
4
3
5
!
18°C
43°C
SET
TURBO
1
2
6
4
3
5
!
AMB
22°C
SET
TURBO
1
2
6
4
3
5
!
H2O
70°C
Stove on and working at full power