PELLET STOVES
Chapter 6
INSTALLATION AND USE MANUAL
page
53
Problems / Causes / Solutions
Technical service - Rights reserved - Reproduction prohibited
Pellets build up in
grate, door glass
gets dirty and flame
is weak.
1.
Insufficient combustion air.
2.
Pellets damp or unsuitable.
3.
Smoke extractor motor broken.
1.
Clean the grate and check that all the
airways are clear.
Carry out a general cleaning of the
combustion chamber and the smoke
duct.
Check that the entry of air is not
obstructed.
Check the state of the door gaskets.
2.
Change the type of pellet.
3.
Check the motor and replace if
necessary.
The smoke
extraction motor
does not work.
1.
No electrical supply to the stove.
2.
The motor is broken.
3.
Defective motherboard.
4.
Control panel broken.
1.
Check the supply voltage and the
protection fuse.
2.
Check the motor and capacitor and
replace if necessary.
3.
Replace electronic board.
4.
Replace the control panel.
The convection air
fan runs
continuously.
1.
Temperature sensor defective or
broken.
2.
Fan broken.
3.
Silencer card of fan defective
1.
Check the operation of the sensor
and replace if necessary.
2.
Check the operation of the motor
and replace if necessary.
3.
Replace silencer card
In the automatic
position the stove
always runs at full
power.
1.
Thermostat set to minimum
2.
Room thermostat in position that
always detects cold.
3.
Temperature sensor defective.
4.
Control panel defective or broken.
1.
Reset the thermostat temperature.
2.
Change the position of the probe
3.
Check the operation of the sensor
and replace if necessary.
4.
Check the panel and replace if
necessary.
The stove does not
run
1.
Lack of electricity supply.
2.
Pellet sensor in lockout.
3.
Fuse blown.
4.
Pressure switch broken (lockout
indicated).
5.
Smoke outlet or duct blocked.
1.
Check that the electric socket is
plugged in and that the main switch
is in position “I”.
2.
Clear lockout by resetting the rear
thermostat, replace the thermostat
if it happens again.
3.
Replace the fuse.
4.
Replace the pressure switch.
5.
Clean the smoke outlet and/or
smoke duct.
Содержание ORCHIDEA HYDRO
Страница 1: ...USE AND MAINTENANCE MANUAL...