Maintenance and cleaning
Technical service - Rights reserved - Reproduction prohibited
C
C
B
A
5.1.4.
Clean the exchanger and the undergrate space every 2/3 days.
Cleaning the exchanger and the undergrate space is a simple operation
but very important for always maintaining performance as declared.
Therefore we recommend cleaning the internal exchanger every 2-3
days, performing these simple operations in sequence:
o
Remove the top
o
Clean the pipe unit
– Using the cool hand supplied,
energetically shake the rods located under top 5-6 times (
C
in
figure 8).
o
This operation removes soot deposited in the exchanger's
smoke ducts when the stove is working normally.
o
Clean the smoke conveyor well
PRIMULA-ORCHIDEA stoves (Figure 9)
– The Primula-Orchidea stoves are equipped with a removable
ash drawer to collect any build-ups of soot and ashes
o
Replace the top when cleaning is complete
If such cleaning is not done every 2-3 days the stove
could go into alarm caused by ash clogging after
several hours of operation.
Figure 8 - Cleaning the internal pipe
unit using scrapers (PRIMULA-
ORCHIDEA)
Figure 9 – Cleaning the lower drawer
(PRIMULA-ORCHIDEA)