5 - POSITIONING
REQUIREMENTS FOR INSTALLATION OF THE PLANT - POSITIONING
The most important thing to do before installation of the boiler is to set aside a suitable area that meets the minimum requirements for
installation.
•
the minimum clearance in front of the product
to allow suitable access for cleaning, maintenance, etc. must be
700 mm
;
• the minimum permissible distance between the back of the product and a wall must be
400 mm
;
• the minimum distance between the top of the product and a wall (ceiling) must be
600 mm
to ensure easy access to the heat
exchanger for cleaning and maintenance (e.g. for removing ash and possible installation of the pellet suction kit);
• the minimum clearance between the product and the wall (side) must be
300 mm
.
COMPACT 14 BOILER MINIMUM REQUIREMENTS
* in the event of suction kit installation