9 - FIRST START-UP
Technical Dept. - All rights reserved - Reproduction is prohibited
GENERAL PRECAUTIONS
Remove any objects that may burn from the brazier (manual, various adhesive labels or any remaining polystyrene).
Check that the brazier is positioned correctly and rests properly on the base.
The first start-up may not be successful as the feed screw is empty and does not always manage to load the required
amount of pellets in time to light the flame.
CANCEL THE ALARM FOR THE LIGHTING FAILURE BY HOLDING DOWN BUTTON 1 (ESC). REMOVE THE PELLET LEFT IN THE
BRAZIER AND REPEAT THE START-UP.
If after repeated attempts, the flame fails to ignite, despite a regular flow of pellets in the brazier, which
must rest snugly against the
slots and be clean without any ash incrustations.
If no anomaly is found during this inspection, there may be a problem with the
product components or installation may not be correct.
REMOVE THE PELLETS FROM THE BRAZIER AND CONTACT AN AUTHORISED TECHNICIAN.
Do not touch the boiler during the first lighting, as it is during this phase that the paint sets. If you touch the paint,
you may expose the steel surface.
If necessary, touch up the paint with the spray can of the specific colour. (See ‘’Pellet stove accessories’’).
It is good practice to ensure effective ventilation in the room during the initial start-up, as the boiler will emit some
smoke and smell of paint.
ATTENTION!
Please ensure the brazier is clear of ALL pellets and ash build up following any failed ignitions. Failure to clear out
the brazier prior to resetting may result in further failed ignitions or in certain conditions an explosive ignition.