INSTALLATION INSTRUCTIONS
(continued)
27
Air intake pipe - Intake connection to wall mounted fan terminal
Locate terminal on wall and predrill mounting holes
where required.
Cut flue inlet tube to length (Flue must extend a
minimum of 50mm past the exit face of wall.) It is
recommended that the tubes are cut slightly longer
and pushed back into wall upon fixing of wall terminal.
Allow flue movement between terminal and last flue
hanging clip.
Ensure ends are burr free and round, test fit flue will
slide inside both the hot exhaust connection and air
intake connection.
Feed air intake flue into connection, ensure inserted
50mm. Fit retaining screw from below.
Push terminal into approximate position and affix onto
wall.
Flue Exhaust Connections - Connection to fan module at appliance
Check flue piece for correct shape and fitment onto
appliance spigot.
FOR DIRECT MOUNT CUT 65MM
– Otherwise cut
the required length
Ensure ends are burr free and round, test fit flue will
slide over connection.
Recommended Silicon
– Non-acetic, neutral cure 150degc or higher temperature rated.
Bostik RTV 926 or similar.
Apply an 8mm thick silicon bead fully around heater connection approx. 10mm from the top.
Apply an 8mm thick silicon bead fully around the lower fan connection spigot approx. 10mm from
the end.