INSTALLATION INSTRUCTIONS
(continued)
Flue Exhaust Connections - Connection to fan module at appliance
(continued)
Locate 2nd clamp onto lower connection and tighten clamp fully.
Wipe excess silicon, visually check connection to ensure connection is fully sealed.
Where fan sits higher, ensure fan assembly is supported on a frame. Where timber framing is used
clearances to flue and fan box must be maintained.
Flue Exhaust Connections - Fit hot exhaust flue pipe from outlet termination to
fan outlet connection
Cut tube to length where required.
Ensure ends are burr free and round, test fit flue will slide over connection.
5m of flexi flue on the exhaust side MUST be used
before prior to converting to polypropylene. Failure to
do this will result in appliance shutdown.
Apply an 8mm thick silicon bead fully around heater
connection approx. 10mm from the top.
Apply an 8mm silicon bead fully around the inside of
the flue end (heater connection end)
Fit flue clamp over flue (loosely).
2
9