Page 7
Specifications
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
The standard setup (without extra memory) can
memorize up to 40 commands, and each channel
utilizes 10 of those. If all 4 channels are used you
can have up to 10 remotes.
Dip Switches
Dip switch 3 must be turned on for sliding door
applications.
Dip Switch
ON
OFF
1
Automatic
closing
activated
Automatic
closing
deactivated
2
Partial
opening active
Illumination
function
3
Side-opening
sectional door
Sectional door
4
Retractable
door
Sectional door
Reset Button
The length of time the reset button is pressed will
define what is reset see below options.
• 1-2 seconds will reset the safety devices
• 5 seconds the force values will be deleted
•
10 seconds the end position (or close) will be
deleted
•
30 seconds will be full factory reset
Содержание Edison Sliding Opener
Страница 1: ...Edison Sliding Opener Installation Manual...