Page 27
Maintenance and Care
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
Maintenance and Care
The use of oil or grease on the chain track or
carriage will reduce conductivity. This may result in
faults due to inadequate electrical contact.
• The use of unsuitable cleaning agents may
damage the surface of the opener. Clean with a
dry lint-free cloth only
Service the opener regularly as directed below. This
ensures safe operation and a long service life of
your opener.
How Often?
What?
How?
Once a month
Test the
emergency
release
See chapter
12.7 in
manufacturer’s
manual
Once a month
Test the
obstacle
detection
See chapter
11.1 in
manufacturer’s
manual
Once a month
Test the safety
sensors
Interrupt the
active safety
sensors while
the door is
closing. The
doors should
stop and open.
Once a year
Test the door
and all moving
parts
As directed
by the door
manufacturer
Once a year
check screws
on door ceiling
and header
Check that
screws are
tight and
tighten if
necessary
As needed
chain and track maintenance
free
As needed
Track
See below
cleaning
instructions
As needed
Cleaning
ceiling
control unit
and carriage
housing
See below
cleaning
instructions
Cleaning
1. Clean track, carriage and control unit housing
• Pull the power plug out of the outlet. If a battery
pack has been installed, remove the control unit
housing cover and disconnect the battery pack.
Check that the power is disconnected.
2. Remove the loose dirt with moist, lint-free cloth
• From the carriage and the control unit housing
• From the track and the inside of the track
3. If applicable install the battery pack in reverse
order of removal
Cleaning Photo Eyes
1.
Clean the housing reflectors with a moist, lint-
free cloth