background image

Sliding Gate Opener

User Manual

GA600AC

Website: www.gatexpertstore.com

E-mail: [email protected]

Содержание GA600AC

Страница 1: ...Sliding Gate Opener User Manual GA600AC Website www gatexpertstore com E mail sales gatexpertstore com...

Страница 2: ...cribed in this manual Unexplained alterations may cause malfunction We are not responsible for any damage caused Do not leak water or any liquid into the controller or other open devices In such a cas...

Страница 3: ...ce for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in the fo...

Страница 4: ...Step 4 Motor Pad Footing 7 Step 5 Fitting Mounting Plate and Motor 8 Step 6 Motor Position Adjustment 9 Step 7 Gear Rack Motor Alignment 9 Step 8 Limit Switch Stops 10 Step 9 Powering on 13 Step 10 Te...

Страница 5: ...direction This will give you an understanding of the way in which the opener will move the gate Figure 2 Note Ensure that the gate opener is unplugged before proceeding with installation Please keep...

Страница 6: ...Release Keys 2 5 Remote Control 2 6 Spring Limit Switch Accessories Box Magnetic Limit Switch Accessories Box 1 6 1 1 Spring Limit Switch Stop 1 For use when installing spring switch limit Spring Stop...

Страница 7: ...et 4 Wireless Keypad 1 5 Alarm Lamp 1 6 WIFI module 1 set Additional remote controls Spare Additional remotes for the automatic gate kit these will need to be paired to the motor Infrared photocell De...

Страница 8: ...the opening and closing motion of gates up to 600kg in weight up to a length of 8m Gate motion is achieved by the rotating output gear of the gate opener driving the gear rack sold separately fitted t...

Страница 9: ...tep 1 Gate Preparation Ensure that the sliding gate is correctly installed The gate is horizontal and level and the gate can glide back and forth smoothly when moved by hand before installing the gate...

Страница 10: ...Step 3 Removing Installing Motor Cover Draw off the sliding cover and turn on the release key Unscrew the two cover screws located at each side of the motor cover Remove the rubber grommet below the...

Страница 11: ...to a suitable position The center line of rack and drive gear should be roughly on a line as in Figure 8 mark it well use a 12mm concrete drill bit to make holes and tap the M8 expansion bolts into th...

Страница 12: ...rs see Figure 9 Pre position the machine according to Figure 10 to ensure that the machine output gears and racks are aligned and that the gears and racks are centered as far as possible see Figure 11...

Страница 13: ...Ensure that the output gear has a minimum clearance of 1 5 2 5mm along the entire length of gear rack fitted to the gate as per Figure 11 Ensure output gear and gear rack are correctly aligned Under...

Страница 14: ...ed to come into contact with the spring magnetic limit switch It is extremely dangerous that without or incorrect installation of the limit switch stops can cause crash of gate damage of internal stru...

Страница 15: ...Test the spring limit switch stops by moving the gate manually until you hear a click making sure contact is made with the spring limit switch on the motor The installation of spring limit switch stop...

Страница 16: ...Switch Stops Closed Position Position gate 150 200mm back from the magnet bracket closed position This will help in making sure you do not slam the gate into the end stop catch when setting the closed...

Страница 17: ...ng remote control or external push button switch to open and then close the gate once then new limit switch stop setting is completed Step 9 Powering on Ensure that the outer cover has been fitted and...

Страница 18: ...m the measurement you have taken to get your final gate closed position The ideal closed final position for the gate frame is 10 15mm from closed gate end catch Testing the Open Position Press remote...

Страница 19: ...n Button J6 Terminal Dip Switches Potentiometers Control Board Programming and Wiring Any works to the 110V 220V AC must only be performed by a licensed electrician Ensure power is off before any modi...

Страница 20: ...e Time Automatic close time setting the gate is operated to open by remote control operation and will close automatically after a few seconds delay 3 OFF 4 ON automatic close delay time is 12s 3 ON 4...

Страница 21: ...switch 5 is at the OFF position Do not turn Dip switch 5 to the ON position VR2 Brake Force Adjustment For adjusting brake force at the limit position during gate opening and closing This should only...

Страница 22: ...ion MOTCOM Motor Common Terminal LAMP L N Connection for warning lamp PE Motor and warning lamp earth Note If require to change the moving direction not only MOT1 and MOT2 wires need to be swapped but...

Страница 23: ...es sold separately Port 12 Open Limit Switch Port 11 Limit Switch Common Port Port 10 Close Limit Switch Port 9 Ground Earth GND Port 8 Photocell input N C If no photocell is fitted use a jumper betwe...

Страница 24: ...use of infrared photocells as an additional safety feature While closing if the ray of the Infrared Photocell is blocked the gate will stop and reverse immediately to protect user and property securit...

Страница 25: ...orth button on remote control is Pedestrian Mode press the forth button while the gate is closed the gate will open 1m wide to allow pedestrian access Figure 19 Remote Control Learning Remove motor ou...

Страница 26: ...Opener User Manual 22 Clearing Remote Controls To delete all paired remote controls press and hold the button S1 till LEARN LED turns on When the LEARN LED turns off all previously paired remote cont...

Страница 27: ...n above Output Terminal Output signal should connect to O S C and COM terminals on the motor control board Position Feedback Terminal Open or Closed in place feedback signal Should connect to open clo...

Страница 28: ...router supports both 5G and 2 4G WIFI please select 2 4G WIFI Download the Tuya or Smart Life App from App Store or Google Play Store During paring make sure your mobile phone and WIFI device is conn...

Страница 29: ...set button on the WIFI device your mobile will search the device automatically Mark If the device can not be found automatically please add it under Add Manually Mark select Socket WIFI and follow its...

Страница 30: ...cording to your gate running travel For example the travel time of opening is 23 sec you can set the run time to be 25s recommended to set it a little bit longer than travel time default setting is 20...

Страница 31: ...the app will send a reminder You can still control the opening and closing but there is no feedback on the app after opened or closed It is suggested to use this WIFI control under your visible sight...

Страница 32: ...annot close 1 Photocell wrongly wired 2 Photocell wrongly installed 3 Photocell is blocked by objects 4 Sensitivity of obstacle is too high Intelligent type 5 Hall sensor parts damaged Intelligent typ...

Страница 33: ...sition 2 Magnetic limit switch badly installed direction 2 Check whether the distance and height between magnetic limit switch and motor reaches to standard requirement Leakage switch tripped Power su...

Отзывы: