GA600AC Sliding Gate Opener User Manual
11
·
Fit limit switch stop onto the top of gear rack at the point where it meets the Spring limit switch
on the motor.
·
Tighten locking screws of limit switch stop.
Open Position
·
Position gate 150-200mm back
from the gate stop open position.
This will help in making sure you
do not slam the gate into the end
stop/catch when setting the open
position under power.
·
Fit limit switch stop onto the top of gear rack at the point where it meets the Spring limit switch
on the motor.
·
Tighten locking screws of limit switch stop.
Test the spring limit switch stops by moving the gate manually until you hear a click, making sure
contact is made with the spring limit switch on the motor.
The installation of spring limit switch stops is shown in figure above.
B. Magnetic Limit Switch
(
6-1-2Accessories
)
Included in your gate opener kit are two magnet limit switch stops with two different polarities: stop
in black color(N), stop in blue color(S). Before installing the magnet bracket, please fix the magnet
on the magnet bracket, and then install the magnet bracket on the proper position of the door gear
bar (refer to Figure 12).
To change the gate opener from right-hand
磁钢
Spring limit switch
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
Gear Rack
Limit Stop
Limit Stop Bracket