background image

Page 26

Accessories

Real Carriage Door & Sliding Hardware  Copyright 2020© all rights reserved

Outdoor Keypad

Keypad Activation

1.  Press and hold the [M] button for about 8 

seconds

•  Both red and amber LED 

lights will light up for about 

2 seconds

Note:

 The lower amber light 

will flash until the upper red 

light comes on. The keypad is 

not activated until the red LED 

illuminates.

Programming Access Code

1.  Press the [P] button

2. 

Press the first button of your 

access code

3.  Press the [P] button

4. 

Enter entire access code

5.  Press the [P] button againt to complete

Programming the Keypad to the Opener

1.  Press the radio button on the control board of 

the motor carriage (this puts it in learn mode)

2.  Enter access code immediately on keypad

Changing Access Code

1.  Press [P] button

2.  Enter existing access code

3.  Press [P] button

4.  Enter a new access code that uses the first 

same first digit (longer is OK)

5.  Press [P] to complete 

Erase Access

1.  Press [M] button

2.  Press [P] button

3. 

Enter 9 digit reset code

4. 

Press [M] button

5.  Press [P] button

6. 

The red and amber LED lights will illuminate for 

2 seconds and all codes are cleared

Note: 

It is important to keep the reset code sticker 

which includes the 9 digit reset code

• 

They keypad will transmit the first digit coide 

from the original code to the opener

Deleting Radio Code

1.  Press and hold learn button in opener until LED 

flashes

2.  Press the desired keypad button

3. 

This will delete the first digit from entry code

Wireless Wall Control

Please see instructions included with the two 

button wall control station for specifications, 

assembly and additional information.

1.  Press radio button once

2.  Press the desired transmitter button

•  The LED blinks orange once

•  The LED lights up red

3.  Radio is now programmed

4. 

Repeat steps 1 and 2 to program additional 

buttons

Содержание Edison Sliding Opener

Страница 1: ...Edison Sliding Opener Installation Manual...

Страница 2: ...ments It is also a good idea to install a surge protector to avoid any damage to the operator The operator can be damaged by power surges or faulty wiring CAUTION All California residents must have a...

Страница 3: ...ackets 16 Attaching Door Bracket 16 Mounting Control Unit 16 Wicket Switch 17 Inserting ACCU battery backup 18 Photo Eyes 18 Autoset Programming 20 Red Limit Stop 20 Autoset 21 Troubleshooting 21 Afte...

Страница 4: ...pre assembled on chain 2 1 Connecting sleeve x2 3 Additional track pieces 4 Chain tensioner for closing end of track 5 Wire Connector open end of track 5 1 Ceiling bracket which is 2 parts 6 Ceiling...

Страница 5: ...are 4 45 lbs 5ft extensions are 44 x 8 x 2 and are 6 95 lbs Additional ceiling bracket part 6 of main box Magnetic coupler Masterlink Chain Rail Extension Additional Parts Box This box includes additi...

Страница 6: ...y one limit switch that needs to be installed and the motor carriage is simply laid out and pre installed on the rails Note For additional information please visit the manufacturer s Sommer manual Tro...

Страница 7: ...liding door applications Dip Switch ON OFF 1 Automatic closing activated Automatic closing deactivated 2 Partial opening active Illumination function 3 Side opening sectional door Sectional door 4 Ret...

Страница 8: ...it switch terminal OPEN limit blue 4 PCB label 5 LEDs opener lighting 6 MEMO slot MEMO terminal 7 USART slot interface 8 BUZZER slot black Warning or alarm buzzer terminal 9 SENSO slot SENSO terminal...

Страница 9: ...transmitter commands USART slot terminal e g module home automation SENSO slot terminal for SENSO humidity sensor BUZZER slot black terminal for warning alarm buzzer LASER slot white terminal for par...

Страница 10: ...or button connector cable of the wall control unit 4 Terminal for relay 5 2 pin Terminal power supply 120 V AC 50 60 hz 6 2 pin Terminal Transformer primary side 120 V AC 50 60 Hz 7 2 pin Terminal 24...

Страница 11: ...ot white Terminal for Lumi supplementary lighting 2 pin Terminal Safety Sensors any polarity 2 pin Terminal wall station or wall button potential free Deinstalling the Control Unit Cover 1 Disconnect...

Страница 12: ...hanges the measurement depending on your application like the height it is mounted above opening Biparting Doors You can utilize either the side mount or ceiling mount option and choose whichever is b...

Страница 13: ...ends on your application Measure from the end of the rail to the where the door bracket attaches to the boomerang arm The angle of the boomerang arm changes which changes the measurement depending on...

Страница 14: ...h the chain across the length of the track Chain Tensioner Note The chain tensioner goes on closing end while as the wire connector is for the open end 1 Slide chain tensioner part 5 into the opening...

Страница 15: ...one side against the top of the rail and the other at the bottom facing each other 4 Slide the pieces together so they interlock 5 To tighten the bolts first hand tighten them and then with a socket o...

Страница 16: ...he boomerang arm and the u fitting assembly to determine the best placement 3 Mark the location of the brace s two mounting holes 4 Cut the door bracket to length if desired and plug the end with the...

Страница 17: ...rain relief back and tighten to prevent wire displacement 17 Connect the blue wire to gn terminal 18 Connect the brown wire to rt terminal 19 Close the housing in reverse order Wicket Switch Installat...

Страница 18: ...in the control unit cover and fasten with the two cable binders 5 Plug the battery pack plug into the ACCU battery slot on the control board 6 Set DIP switch 3 to ON on the control unit only 7 Plug t...

Страница 19: ...r Mount one safety sensor to the left and one to the right of the door It does not matter which safety sensor is installed on the left or on the right side Installation 1 Look for a suitable installat...

Страница 20: ...will allow you to move the door freely to see where the door needs to stop 2 Place the doors in open position 3 Position the red stop accordingly Tighten the limit back down 4 Place the doors in the...

Страница 21: ...move Each hop equals a 1 4 jump and you need a total of an inch 9 Pull emergency cord to engage the motor 10 Press the 1st button to activate the opener to return the open limit The opener will contin...

Страница 22: ...will correct the issue but motor will run at slower speed Redo autoset process Note For installation videos look up Roman Troyer s youtube channel and Sommer USA After Autoset Completion Battery Pack...

Страница 23: ...se the two buttons 3 This puts it in learn mode and will remain for 30 seconds 4 Press any button on your new remote to clone it 5 The opener light will remain steady 6 Second remote is programmed SOM...

Страница 24: ...d release 9 Repeat the press hold release sequence a second time to activate the door 10 You may need to repeat this sequence for pressing radio button on the motor carriage and then pressing the Home...

Страница 25: ...ible solutions Data backup Generation backup and loading of own user profiles on to the drive Can program features like humidity venting power sensitivity speed and lighting Recommended to only be use...

Страница 26: ...Press P button 4 Enter a new access code that uses the first same first digit longer is OK 5 Press P to complete Erase Access 1 Press M button 2 Press P button 3 Enter 9 digit reset code 4 Press M but...

Страница 27: ...the door is closing The doors should stop and open Once a year Test the door and all moving parts As directed by the door manufacturer Once a year check screws on door ceiling and header Check that s...

Страница 28: ...Real Carriage Door Sliding Hardware Copyright 2020 all rights reserved Please visit our website and download our most up to date manual Call us directly at 1 253 853 3815 for additional assistance...