background image

9

4a. Telemetry – TEL (Remote Switching)

The TEL button should be selected if the illuminator is to be turned 

on/off using a remote switch or input.

The TEL input can be used in various ways:
1. Turn the light on (night) and off (day) automatically via the photocell. This 

is the standard factory setting – and no further action is required

2. Turn the light on and off from a remote switch or input
3. Used in conjunction with the Timer Function to turn the light on for a pre-

defined period of time. (See section 4c below).

Factory Default = Telemetry TEL Enabled.

See detailed wiring instruction - section 4.

4b. Telemetry - DIM (Remote Dimming)

The remote dimming feature allows the brightness of the VARIO2 

illuminator to be controlled remotely using the telemetry input wires. 

Use the DIM button to select this function. 

When the DIM function is selected, a telemetry input (Telemetry input 

wires joined) will vary the brightness up and down. When the telemetry 

input  is  first  applied,  it  will  dim  the  light  until  the  input  stops  (orange 

and purple wires no longer joined), the illuminator will then stay at that 

brightness level. Further telemetry input will continue to dim the light to its 

lowest output. Once it hits its lowest setting, it will start to brighten again.  

A further input will then continue to brighten the light further to its highest 

output or until the input stops.
Note: Repeated input activation of the telemetry wires continues to dim or 

brighten the illuminator repeatedly. 
Please note that Remote Dim is disabled by pressing TEL button (see 4a 

above). After setting a specific light level using the DIM function, if Telemetry-

TEL is enabled, the last power level set when using the DIM function will be 

remembered and used by the system – unless a new power adjust button 

is selected.

Factory Default =Telemetry DIM Disabled.

See detail on Telemetry input wires - section 4

VARIO2 POE (Non Premium): Using the DIM function on the remote will just 

cycle the power up and down continuously, until the user presses the TEL 

button. (Brightness adjustment as per VARIO2 / VARIO2 POE Premium is not 

possible.)

Содержание VARIO2 series

Страница 1: ...ry Input 4a Telemetry TEL Remote Switching 4b Telemetry DIM Remote Dimming 4c Timer Function 5 LED Status Indicators Enable Disable 6 Restore Factory Default Settings Stored Memory 7 Disable Remote Co...

Страница 2: ...are available in Programming Mode Note If a PIN has been set the unit will not enter programming mode on power up refer to section 10 for more details Programing mode will automatically be disabled af...

Страница 3: ...Off 4a TEL Select this option to turn lamp on off remotely from a remote input or switch This is the factory default setting 4b DIM Select DIM to dim lamp remotely from an input or switch First input...

Страница 4: ...inator The LEDs provide important operating and status information The Infra Red receiver for the Remote Control commands is also on the base of the unit and the Remote Control should be pointed in th...

Страница 5: ...N Remote control IR receiver problem Max VRC distance is 8m 26ft FLASHING AMBER Indicates the unit is in programming mode Programming Mode Only SOLID AMBER Indicates that a valid command is being rece...

Страница 6: ...e Programming mode automatically disabled after 7 days or until the user actively disables the programming mode or the unit times out 30 minutes after any press of the manual buttons on the illuminato...

Страница 7: ...ux On 30 Lux Off IMPORTANT NOTE When the Photocell is disabled VARIO2 VARIO2 POE Premium The illuminator will turn on off from a telemetry input regardless of ambient lighting conditions VARIO2 POE no...

Страница 8: ...wires Snip the end of the cable and then use the two core cable as normal VARIO2 POE not premium Telemetry input not available Illuminator will automatically be controlled by the photocell VARIO2 Hyb...

Страница 9: ...put is first applied it will dim the light until the input stops orange and purple wires no longer joined the illuminator will then stay at that brightness level Further telemetry input will continue...

Страница 10: ...period and have the unit operate under standard telemetry conditions press Timer Disabled Note The timer only functions when the Telemetry Input Wires are used with a remote switch alarm system PIR de...

Страница 11: ...is status indicator function can be switched on and off by pressing the STATUS button This is the only button that has two states It is possible for this function to be enabled disabled even if progra...

Страница 12: ...continuously for at least 4 seconds This is to avoid the possibility of activating this feature accidentally Note Restoring to factory settings is not possible if a PIN has been set The factory defau...

Страница 13: ...e the RHS LED indicator is Off After 7 days of continuous power the illuminator will automatically disable the remote and change to Operating mode Please note To enable programming mode again after re...

Страница 14: ...ntrol Set Up button is pressed again and held for 4 seconds the manual buttons will be disabled When completed this is shown by both indicator LEDs flashing RED Note This command can only be used with...

Страница 15: ...Red source is pointing at the remote receiver which is on the bottom of the unit Ensure that there is a clear line of site between the unit and remote with no possible obstructions In extreme sunligh...

Страница 16: ...ssales rayteccctv com www rayteccctv com Check battery on remote CR2025 Test 3 volt battery and replace if necessary Ensure battery has clean contacts Remote failure test with new remote If the remote...

Отзывы: