background image

4

6.  To restore all factory settings press RESET button. Defaults shown in 

section 6. This button must be pressed continuously for 

4 seconds

 

to activate function.

7. 

Press this button to disable programming mode and enter 

Operating mode. Button must be depressed for at least  

4 seconds

. Only do this when you are happy with the set-up 

and installation of your unit.

8.  Security PIN set (See section 10 of this guide for more details):  

Use the remote if you want to set a security PIN on your illuminator .

VARIO2 Hybrid: PIN function not available

1.  LED Status Indicators, Using the Remote and 

Operating Modes

There are two multi-coloured LEDs, visible on the base of the 

VARIO2 illuminator. The LEDs provide important operating and 

status information. The Infra-Red receiver for the Remote-Control 

commands is also on the base of the unit – and the Remote Control 

should be pointed in 

this

 direction during programming. Most 

functions respond immediately to pressing the required button – 

however three functions require the button to be held for 4 seconds 

continuously to avoid accidental programming: 1. Restore Factory 

Default, 2. Disable Remote Control Set-up and 3. PIN Function.  

The Remote Control is designed to operate at distances up to 8 

metres.

The status information provided by each of these LEDs differs 

depending on which of the two operating modes the VARIO2 

illuminator is in: (A) Programming 

OR

 (B) Normal Operating.

VARIO2 Hybrid: These illuminators have different LED indicators and 
feedback. Please refer to the VARIO2 Hybrid Illuminator Instructions.

Содержание VARIO2 series

Страница 1: ...ry Input 4a Telemetry TEL Remote Switching 4b Telemetry DIM Remote Dimming 4c Timer Function 5 LED Status Indicators Enable Disable 6 Restore Factory Default Settings Stored Memory 7 Disable Remote Co...

Страница 2: ...are available in Programming Mode Note If a PIN has been set the unit will not enter programming mode on power up refer to section 10 for more details Programing mode will automatically be disabled af...

Страница 3: ...Off 4a TEL Select this option to turn lamp on off remotely from a remote input or switch This is the factory default setting 4b DIM Select DIM to dim lamp remotely from an input or switch First input...

Страница 4: ...inator The LEDs provide important operating and status information The Infra Red receiver for the Remote Control commands is also on the base of the unit and the Remote Control should be pointed in th...

Страница 5: ...N Remote control IR receiver problem Max VRC distance is 8m 26ft FLASHING AMBER Indicates the unit is in programming mode Programming Mode Only SOLID AMBER Indicates that a valid command is being rece...

Страница 6: ...e Programming mode automatically disabled after 7 days or until the user actively disables the programming mode or the unit times out 30 minutes after any press of the manual buttons on the illuminato...

Страница 7: ...ux On 30 Lux Off IMPORTANT NOTE When the Photocell is disabled VARIO2 VARIO2 POE Premium The illuminator will turn on off from a telemetry input regardless of ambient lighting conditions VARIO2 POE no...

Страница 8: ...wires Snip the end of the cable and then use the two core cable as normal VARIO2 POE not premium Telemetry input not available Illuminator will automatically be controlled by the photocell VARIO2 Hyb...

Страница 9: ...put is first applied it will dim the light until the input stops orange and purple wires no longer joined the illuminator will then stay at that brightness level Further telemetry input will continue...

Страница 10: ...period and have the unit operate under standard telemetry conditions press Timer Disabled Note The timer only functions when the Telemetry Input Wires are used with a remote switch alarm system PIR de...

Страница 11: ...is status indicator function can be switched on and off by pressing the STATUS button This is the only button that has two states It is possible for this function to be enabled disabled even if progra...

Страница 12: ...continuously for at least 4 seconds This is to avoid the possibility of activating this feature accidentally Note Restoring to factory settings is not possible if a PIN has been set The factory defau...

Страница 13: ...e the RHS LED indicator is Off After 7 days of continuous power the illuminator will automatically disable the remote and change to Operating mode Please note To enable programming mode again after re...

Страница 14: ...ntrol Set Up button is pressed again and held for 4 seconds the manual buttons will be disabled When completed this is shown by both indicator LEDs flashing RED Note This command can only be used with...

Страница 15: ...Red source is pointing at the remote receiver which is on the bottom of the unit Ensure that there is a clear line of site between the unit and remote with no possible obstructions In extreme sunligh...

Страница 16: ...ssales rayteccctv com www rayteccctv com Check battery on remote CR2025 Test 3 volt battery and replace if necessary Ensure battery has clean contacts Remote failure test with new remote If the remote...

Отзывы: