4
6. To restore all factory settings press RESET button. Defaults shown in
section 6. This button must be pressed continuously for
4 seconds
to activate function.
7.
Press this button to disable programming mode and enter
Operating mode. Button must be depressed for at least
4 seconds
. Only do this when you are happy with the set-up
and installation of your unit.
8. Security PIN set (See section 10 of this guide for more details):
Use the remote if you want to set a security PIN on your illuminator .
VARIO2 Hybrid: PIN function not available
1. LED Status Indicators, Using the Remote and
Operating Modes
There are two multi-coloured LEDs, visible on the base of the
VARIO2 illuminator. The LEDs provide important operating and
status information. The Infra-Red receiver for the Remote-Control
commands is also on the base of the unit – and the Remote Control
should be pointed in
this
direction during programming. Most
functions respond immediately to pressing the required button –
however three functions require the button to be held for 4 seconds
continuously to avoid accidental programming: 1. Restore Factory
Default, 2. Disable Remote Control Set-up and 3. PIN Function.
The Remote Control is designed to operate at distances up to 8
metres.
The status information provided by each of these LEDs differs
depending on which of the two operating modes the VARIO2
illuminator is in: (A) Programming
OR
(B) Normal Operating.
VARIO2 Hybrid: These illuminators have different LED indicators and
feedback. Please refer to the VARIO2 Hybrid Illuminator Instructions.