12
6. Restore Factory Default Settings & Stored
Memory
Once the VARIO unit has been programmed, the settings will be
stored in non-volatile (stored) memory. These settings are saved
and reloaded if the illuminator experiences loss of power. If you
wish to restore the unit back to its original factory default settings, this can
be achieved when the unit is in programming mode by pressing the RESET
button. To activate this feature, the button must be pressed continuously for
at least
4 seconds
. This is to avoid the possibility of activating this feature
accidentally.
Note
: Restoring to factory settings is not possible if a PIN has been set.
The factory default settings are:
• Power Set to 100% of Maximum
• Photocell set to Medium Sensitivity Level:
10 Lux On, 30 Lux Off
• Timer Disabled
• Telemetry -TEL Enabled
• Telemetry Input wires soldered together for automatic photocell
operation of unit (VARIO2 POE Non Premium -
No Telemetry wires, photocell activates automatically)
• Telemetry -DIM Disabled
• LED Status Indicators Enabled
• Programming Function Enabled for 7 days
VARIO2 Hybrid: Programming Function Enabled for 4 Weeks