2
VARIO1 Products
Alternative Remote Instructions required - Please contact Raytec.
VARIO2 Remote – Quick Set Up Instructions
1. At power up, the unit enters programming mode:
SOLID GREEN: Power Applied
FLASHING GREEN: Remote control IR receiver problem (Max VRC
distance is 8m (26ft)
FLASHING AMBER: Indicates the unit is in programming mode
(Programming Mode Only)
SOLID AMBER: Indicates that a valid command is being received
from the remote (Programming Mode Only)
FLASHING RED: Voltage supply problem detected
SOLID RED: Illuminator fault detected
All functions of the remote control and buttons are available in
Programming Mode.
Note:
If a PIN has been set the unit will not enter programming mode
on power up (refer to section 10 for more details).
Programing mode will automatically be disabled after 7 days or until
the user actively disables the programming mode or 30 minutes after
any press of the manual buttons
VARIO2 Hybrid: Programming mode automatically disabled after 4
weeks
2. If required: Adjust Power
Press 5 for 100% power, 4 for 80%, 3 for 60%, 4 for 40% and 2 for
20% power.
Factory Default = 100%
3. If required: Adjust Photocell Sensitivity. Press:
Top Button for Low Sensitivity:
25 Lux On 50 Lux Off
2nd Button for Medium Sensitivity: 10 Lux On 30 Lux Off
3rd Button for High Sensitivity:
5 Lux On 15 Lux Off
Bottom button to disable photocell
Factory Default = Medium Sensitivity