Fig. 2

A

Pressure gauge

B

Green led

C

2-digit LED display

D

Red led

E

Temperature selector space heating

F

Mode selector switch

G

Temperature selector Domestic Hot Water

A

B

C

D

E

F

G

Control board

F

Off/reset

 - Select this position when the boiler needs to be

reset or switched off.

Summer mode

 - The domestic hot water function provided

by the water tank is activated. The display indicates the
storage tank temperature (only with the external water tank
connected with a sensor).

Winter mode 

- The boiler produces hot water for heating

and, if connected to an external water tank, it provides
domestic hot water. The display indicates the boiler flow tem-
perature.

Winter mode tank temperature

 - The boiler produces hot

water for heating and, if connected to an external water tank
with a sensor, it provides  domestic hot water. The display
indicates the storage tank temperature.

Temperature selector

 

DHW

- Move the temperature selector

clockwise to increase the hot water temperature in the water
tank or counter-clockwise to reduce the temperature (working
only if a tank sensor is connected).

Temperature selector Heating

 - Move the temperature

selector clockwise to increase the heating temperature or
counterclockwise to reduce the temperature.

2-digit LED display 

- Displays the temperature according

the mode selector switch. During a fault condition, the
appropriate code will be displayed (refer to the installation
instructions regarding fault codes).

Green LED lit

 - Boiler is working/responding to a heating/

tank request (flame ON).

Red LED lit

  - Boiler has identified a fault and has shut down.

Refer to installation instructions on how to reset.

Pressure gauge

 - Ensure the system pressure is set

correctly (minimum 7 p.s.i. (0.45 bar))

Содержание XPAK 85

Страница 1: ......

Страница 2: ......

Страница 3: ...p up the system pressure 9 How to reset the boiler 9 BOILER FAULT CODES How to shut down the system for short periods 9 How to shut down the system for long periods 9 How to care for the boiler 9 WHAT...

Страница 4: ...covered or have any blockage to the flow of fresh air to the boiler WARNING Risk of electrical shock More than one disconnect switch may be required to de energize the equipment before servicing WARN...

Страница 5: ...s POUR VOTRE S CURIT LISEZ AVANT DE METTRE EN MARCHE instructions du fornisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Ne poussez ou tournez la manette d admissi...

Страница 6: ...ake 13 Blocked flue switch 14 Top automatic air vent 15 Flow sensor 16 High limit thermostat 17 Ignition transformer 18 Sensing Electrode 19 Spark Electrode 20 Top automatic air vent drain pipe 21 Con...

Страница 7: ...rnal water tank with a sensor it provides domestic hot water The display indicates the storage tank temperature Temperature selector DHW Move the temperature selector clockwise to increase the hot wat...

Страница 8: ...he display temperature Fig 3 dot in the middle means hundred Fig 3 dot on RIGHT side means DHW mode Fig 3a example When the status indicator Green is lit it indicates that the flame is detected and th...

Страница 9: ...for short periods by simply turning the mode selector switch to the off position It is also advisable to turn off the main water supply to the house How to shut down the system for long periods If the...

Страница 10: ...flow of combustion or ventilation air to heater 5 Follow pre start up check in the Start up section 6 Check operation of safety devices Refer to manufacturers instructions 7 To avoid potential of seve...

Страница 11: ...full fire for natural gas and 10 0 for propane gas Carbon monoxide should be 130 ppm 5 Check for leaks at all valve fittings using a soapy water solution while heater is operating Test other operatin...

Страница 12: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468...

Отзывы: