How to top-up the system pressure (Fig. 5-6)

The system pressure must be checked periodically to ensure the
correct operation of the boiler. The needle on the gauge should
be reading between 15-22 psi (1-1.5 bar) when the boiler is in an
off position and has cooled to room temperature. If the pressure
requires ‘topping-up’ use the following instructions as a guide.
- Locate the filling valve connections (usually beneath the boiler,

see Fig. 5).

- Attach the filling loop to both connections (if available).
- Open the filling valve slowly until you hear water entering the

system.

- Close the filling valve when the pressure gauge (on the boiler)

reads between 15-22 psi (1-1.5 bar)

- Remove the filling loop from the connections.

How to reset the boiler

When the red fault LED is illuminated, the boiler will need to be
reset manually. Before resetting the boiler, check what action is
required to be taken, using the information on the fault code table
below. Allow a period of two minutes to elapse before rotate the
status mode knob. To reset the alarm, the status mode knob must
be rotated to the OFF position.

Fig. 6

flow/return

pipe

control

valve

temporary

connection

control

valve

supply

pipe

double

check valve

Fig. 5

 correct

pressure

value

IMPORTANT

If the boiler requires to be reset frequently, it may be indicative of
a fault, please contact your installer or Raypak Customer Services
for further advice.

How to shut down the system for short
periods

The system and boiler can be shut down for short periods by
simply turning the mode selector switch to the off position. It is also
advisable to turn off the main water supply to the house.

How to shut down the system for long
periods

If the house is to be left unoccupied for any length of time –
especially during the winter – the system should be thoroughly
drained of all water. The gas, water, and electricity supply to the
house should also be turned off. For more detailed advice contact
your installer.

How to care for the boiler

To clean the outer casing use only a clean damp cloth. Do not
use any scourers or abrasive cleaners. Damage to the cabinet
finish may occur.

CODE

ACTION REQUIRED

AL10 Reset boiler. Call service technician if fault re-occurs

AL20 Reset boiler. Call service technician if fault re-occurs

AL21 Reset boiler. Call service technician if fault re-occurs

AL26 Reset boiler. Call service technician if fault re-occurs

AL28 Reset boiler. Call service technician if fault re-occurs

AL29 Reset boiler. Call service technician if fault re-occurs

AL34 Reset boiler. Call service technician if fault re-occurs

AL40 Check system pressure and refill if necessary.

Reset boiler. Call service technician if fault re-occurs

AL41 Check system pressure and refill if necessary.

Call service technician if fault re-occurs

AL52 Call service technician

AL55 Call service technician

AL60 Call service technician

AL71 Call service technician if fault re-occurs

AL73 Call service technician if fault re-occurs

AL74 Reset boiler. Call service technician if fault re-occurs

AL79 Reset boiler. Call service technician if fault re-occurs

AL91 Main heat exchanger needs cleaning. Call service

technician

BOILER FAULT CODES

Содержание XPAK 85

Страница 1: ......

Страница 2: ......

Страница 3: ...p up the system pressure 9 How to reset the boiler 9 BOILER FAULT CODES How to shut down the system for short periods 9 How to shut down the system for long periods 9 How to care for the boiler 9 WHAT...

Страница 4: ...covered or have any blockage to the flow of fresh air to the boiler WARNING Risk of electrical shock More than one disconnect switch may be required to de energize the equipment before servicing WARN...

Страница 5: ...s POUR VOTRE S CURIT LISEZ AVANT DE METTRE EN MARCHE instructions du fornisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Ne poussez ou tournez la manette d admissi...

Страница 6: ...ake 13 Blocked flue switch 14 Top automatic air vent 15 Flow sensor 16 High limit thermostat 17 Ignition transformer 18 Sensing Electrode 19 Spark Electrode 20 Top automatic air vent drain pipe 21 Con...

Страница 7: ...rnal water tank with a sensor it provides domestic hot water The display indicates the storage tank temperature Temperature selector DHW Move the temperature selector clockwise to increase the hot wat...

Страница 8: ...he display temperature Fig 3 dot in the middle means hundred Fig 3 dot on RIGHT side means DHW mode Fig 3a example When the status indicator Green is lit it indicates that the flame is detected and th...

Страница 9: ...for short periods by simply turning the mode selector switch to the off position It is also advisable to turn off the main water supply to the house How to shut down the system for long periods If the...

Страница 10: ...flow of combustion or ventilation air to heater 5 Follow pre start up check in the Start up section 6 Check operation of safety devices Refer to manufacturers instructions 7 To avoid potential of seve...

Страница 11: ...full fire for natural gas and 10 0 for propane gas Carbon monoxide should be 130 ppm 5 Check for leaks at all valve fittings using a soapy water solution while heater is operating Test other operatin...

Страница 12: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468...

Отзывы: