The digital thermostat models are programmed to display a variety of status and diagnostic messages, depend-
ing on the operating conditions.
NOTE:
The LCD temperature display may not agree with the temperature reading of your pool or spa ther-
mometer. The heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool
or spa, the water temperature at the inlet to the heater may differ from that observed at a given location in the
pool or spa.
Display
Condition
Heating
Call for heat established, flame pres-
ent
Spark
Spark operating
No
Demand
Heat demand is satisfied or the unit is
in its 30-second post-purge timeout
Pre Purge
Blower is powered for a 45-second
purge prior to trial for ignition.
The following conditions are displayed in Pool, Spa
and Remote modes.
Display
Condition
Sensor
Failure
Thermistor temperatures disagree
by more than 2°F
Sensor Open
Thermistor sensor failed open.
(Below -25°F)
Sensor Short
Thermistor sensor failed short.
(Above 213°F)
Flame w/o
CFH
Board is sensing flame when both
main and pilot valves are command-
ed shut.
MV Output
Fault
Main gas valve output is not in com-
manded state.
Internal Fault
Board fault, replace board.
EEPROM
Fault
Memory fault. Cycle power and
reset set points. Replace board if
fault does not clear.
Clock/
Fireman Sw
Time clock/fireman switch circuit is
open.
Low Temp
Lockout
Water temperature below 36°F.
The following heat status messages are displayed in
Pool, Spa, and Remote modes when there are no
active fault conditions.
The following conditions are displayed only while there
is a demand for heat present.
Display
Condition
Water Sw
Open
Water flow switch open.
Blocked Vent
Blocked switch is open.
Hi Limit 1
Fault
High limit 1 open.
Hi Limit 2
Fault
High limit 2 open.
Vent Temp
Limit
Unused spare circuit is open.
Air Flow Sw
Open
Air pressure switch not closed with-
in 10 seconds of blower activation.
Air Flow Sw
Closed
Air pressure switch is closed prior to
the blower being turned on.
Fan Lockout
3 fan switch faults within same heat
demand cycle, power must be
cycled to clear the fault.
Ignition
Lockout
(Propane Tab
Broken)
Alternating with “Ign Failure” -
Failure to ignite and sense flame in
4-second trial for ignition with
Propane “15” or “90” tab broken.
Ign 60min
Delay
(Propane Tab
Not Broken)
After 3 failed ignition attempts, the
heater will lock out for 60 minutes
before retrying.
EOL
End of Line Test. Mode button stuck
in closed position.
STATUS AND
DIAGNOSTICS
Table K: Display Messages