Alarm name
Alarm type
Description
Action
SeaTalk fail
Safety Alarm
Total
SeaTalk data
transmission
problem.
• Check
connections
for short or
open circuit.
• Check
system for
device fault.
• Pilot drops to
standby and
alarm times
out after 10
seconds.
EEPROM
corruption
Safety Alarm
A corruption
of critical
configuration
data has
occurred.
• Pilot drops to
standby and
alarm times
out after 10
seconds.
No Pilot
Safety Alarm
The Pilot
controller
has lost
communications
with the course
computer;
this alarm
is generated
by the Pilot
controller.
• Check
Seatalk or
Seatalk
ng
bus wiring
between SPX
and Pilot
controller.
• Check that
the course
computer is
powered up.
No Compass
Safety Alarm
Compass is not
connected.
• Check
connections
and compass
transducer.
Rate Gyro fault
Safety Alarm
The gyro sensor
has failed.
• Internal
Gyro failure,
investigate
fault and
Consult a
Raymarine
Service
Agent.
Current Limit
Safety Alarm
Drive overload
current
exceeded.
• Check drive
unit and
connections
for stall or
short circuit
wiring
• Pilot drops to
standby and
alarm times
out after 10
seconds.
Rudder
reference unit
failure
Safety Alarm
Rudder
Reference
connection has
been lost, or
exceeded it's
limits.
Rudder
reference
transducer has
failed while in
auto. Angle
is more than
50 degrees or
connection to
rudder reference
is lost
• Pilot drops to
standby and
alarm times
out after 10
seconds.
AutoLearn fail
1 (not carried
out)
Safety Alarm
Autolearn has
not been carried
out
• Restart
AutoLearn.
Alarm name
Alarm type
Description
Action
AutoLearn
fail 2 (Manual
intervention)
Safety Alarm
Manual
intervention
during autolearn
• Restart
AutoLearn.
AutoLearn fail
3 (Compass or
drive error)
Safety Alarm
Investigate
compass or
drive fault
• Restart
AutoLearn.
AutoLearn fail
4
Safety Alarm
AutoLearn has
failed due to
compass or
drive error.
• Restart
AutoLearn.
AutoLearn fail
5
Safety Alarm
AutoLearn has
failed due to
motor going into
current limit.
• Restart
AutoLearn.
AutoLearn fail
6
Safety Alarm
AutoLearn has
failed as boat
went into spin
i.e. motor did
not drive the
rudder back to
opposite side.
• Restart
AutoLearn.
Turn rate too
high
Safety Alarm
Indicates an
excessive rate
of turn whilst
linearizing
the fluxgate
compass.
Initiated in
Calibration
mode.
• Reduce rate
of turn.
Power & Motor
Cables are
swapped
Safety Alarm
If the motor
pair and the
power pair are
swapped.
• Swap motor
and power
wires at
the course
computer
Low battery
Alarm
Will appear
when Battery
goes below
threshold set.
10 V (default)
• Check
batteries or
power supply
• Will silence
if current
goes above
threshold.
• Press cancel.
No Navigation
data
Alarm
Indicates
absence of one
of the following
primary control
data items:
•
Compass –
Auto, Track &
Wind modes.
• XTE – Track
mode.
• Wind angle
– Wind vane
mode.
• Check the
correct
navigation
data is
available for
the mode
selected.
• Check the
data source.
Pilot start up
Alarm
Will display
start up for
20 seconds
everytime the
pilot is powered
up
• Self
cancelling.
Pilot controller alarms
71
Содержание P70
Страница 2: ......
Страница 4: ......
Страница 12: ...12 p70 p70R...
Страница 22: ...22 p70 p70R...
Страница 28: ...28 p70 p70R...
Страница 29: ...Chapter 5 Mounting Chapter contents 5 1 Mounting on page 30 Mounting 29...
Страница 36: ...36 p70 p70R...
Страница 44: ...44 p70 p70R...
Страница 62: ...62 p70 p70R...
Страница 68: ...68 p70 p70R...
Страница 69: ...Chapter 11 Pilot controller alarms Chapter contents 11 1 Alarms on page 70 Pilot controller alarms 69...
Страница 85: ...Chapter 13 Troubleshooting Chapter contents 13 1 Troubleshooting on page 86 Troubleshooting 85...
Страница 90: ...90 p70 p70R...
Страница 103: ......
Страница 104: ...www raymarine com...