![Rayburn 370 SFW Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/rayburn/370-sfw/370-sfw_installation-instructions-manual_789451026.webp)
10
NOTE - DO NOT SLAM SHUT THE DOORS
AS THIS WILL LEAD TO DAMAGE TO THE
DOOR HANDLES.
AIR SUPPLY
A permanent unobstructed air vent communicated
directly to outside air or an adjacent room which itself
has a permanent air vent to outside is required.
Any air inlet grilles must be positioned so that they are
not liable to blockage.
It is not permissible to use an air extraction device in
the same room as the appliance, unless additional
ventilation is provided to prevent any adverse effect
on the flue.
Effect of Extractor Fan
Avoid if possible the installation of an extractor fan in
the same room as the cooker. Compensating air inlets
must be introduced equivalent to the capacity of the
fan when fitted.
The Cooker should not be installed at zero clearance
to combustible materials. The sides should have a
minimum clearance of at least 7.5 cm (3”) from com-
bustible materials unless otherwise fully insulated.
This cooker is supplied with a back filler piece which
should be used with fitting the cooker between kitchen
units. This filler piece is mounted to the wall behind
the cooker using the appropriate screws and rawl
plugs (not supplied) and allows adequate clearance
from the front of the cooker to the front of the kitchen
units for door opening (see Fig.5 & 5a)
COOKER CLEARANCE
CHIMNEY FIRES
Prevention: Chimney fires do not occur in clean, in-
tact, properly installed chimneys. Have a professional
chimney sweep clean and inspect your appliance at
least once a year. More frequent cleaning may be re-
quired, based on the type of fuel burned and the fre-
quency of use. In general, an older appliance or one
that is used frequently, will require more than one
clean per year.
Detection:
The first indication of a chimney fire is
usually the noise - a roaring sound grows louder as
the fire’s intensity increases. Clouds of black smoke
and sparks will be seen exiting the top of the chimney;
in severe fires, flames can extend several feet about
the chimney.
Action:
In case of a chimney fire follow these steps
but do not put yourself or others in peril:
1. Call the fire brigade immediately.
2. Get everyone out of the property.
3. Close down the air supply to the appliance i.e. the
primary air spinner and the flue damper. Limiting
the fires air supply will reduce its intensity. If there
is a damper in the chimney connector, plug or
close the opening.
4. If a fire extinguisher is available, open the
appliance door just enough to insert the nozzle of
a 10lb, dry chemical fire extinguisher rated for
Class ABC fires. Discharge the entire content of
the fire extinguisher into the appliance and shut the
door.