check all seals for soundness and check that the flue
is functioning correctly and that all products of com-
bustion are vented safely to atmosphere via the chim-
ney terminal.
On completion of the installation and commissioning
ensure that the operating instructions for the stove are
left with the customer. Advise the user what to do
should smoke or fumes be emitted from the stove.
Building Regulations require that whenever a new or
replacement fixed solid fuel or wood/biomass appli-
ance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appli-
ance. Further guidance on the installation of the car-
bon monoxide alarm is available in BS EN
50292:2002 and from the alarm manufacturer’s
instructions.
CO ALARM
10
WARNING:-
If the CO Alarm sounds unexpectedly:-
1. Open Doors and windows to ventilate the
room and then leave the premises.
2. Let the fire go out.
Provision of an alarm must not be considered a
substitute for either installing the appliance cor-
rectly or ensuring regular servicing and mainte-
nance of the appliance and chimney system.
Your installer should have fitted a CO alarm in the
same room as the appliance. If the alarm sounds
unexpectedly, follow the instructions given under
“Warning Note” below.