27
DECIMAL PLACE LOCATIONS
11. DECIMAL SHIFT
The DECIMAL SHIFT feature is used to increase system accuracy at low application rates. Shifting
of the decimal point is done during the entry of METER CAL. After entering METER CAL mode,
depress the decimal shift
, enter the meter calibration constant number, and depress .
The sequence to unshift the decimals while in METER CAL is to enter the meter calibration constant
number and depress . The following table illustrates how shifting the decimal point can
increase system accuracy.
US
METRIC
TURF
UNSHIFT
SHIFT
UNSHIFT
SHIFT
UNSHIFT
SHIFT
RATE DISPLAY
000.0
00.00
0000
000.0
00.00
00.00
RATE 1 CAL
000.0
00.00
0000
000.0
00.00
00.00
RATE 2 CAL
000.0
00.00
0000
000.0
00.00
00.00
TANK VOLUME
0000
000.0
0000
000.0
000.0
000.0
TOTAL AREA
000.0
000.0
000.0
000.0
0000
0000
TOTAL VOLUME
0000
000.0
0000
000.0
000.0
000.0
FIELD AREA
000.0
000.0
000.0
000.0
0000
0000
FIELD VOLUME
0000
000.0
0000
000.0
000.0
000.0
VOL/MINUTE
0000
000.0
0000
000.0
000.0
000.0
AREA/HOUR
000.0
000.0
000.0
000.0
0000
0000
RATE +/-
000.0
00.00
0000
000.0
00.00
00.00
LOW TANK LEVEL
0000
000.0
0000
000.0
000.0
000.0
LOW VOL/MIN
0000
000.0
0000
000.0
000.0
000.0
When entering RATE 1 CAL and RATE 2 CAL, remember that 2 GPA [20 lit/ha] is entered as 2.0 [20.0]
when unshifted and 2.00 [20.00] when shifted.
Содержание SCS 460
Страница 1: ...SCS 460 3 TIER DRIVER INSTALLATION AND SERVICE MANUAL...
Страница 3: ......
Страница 5: ...Manual Rev A SCS 460 3 Tier Driver 02 02 016 0159 888...