MOUNTING THE FLOW METER AND PRESSURE
TRANSDUCER
FLOWMETER
1)
Mount Flow Meter in the area of the boom valves per Figure 4. All flow through Flow Meter must
go to booms only, i.e., no return line to tank or pump after Flow Meter.
2)
Mount Flow Meter horizontal to the ground. Use the bracket to secure the Flow Meter.
3)
For best results, allow a minimum of 7 1/2 inches [20 cm] of straight hose on inlet of Flow Meter.
Bend radius of hose on outlet of Flow Meter should be gradual.
4)
Flow must be in direction of arrow on Flow Meter.
FIGURE 4
NOTE:
It is essential, when using suspensions, that the system be thoroughly rinsed out
each day after use.
PRESSURE TRANSDUCER
1)
Mount pressure transducer, part #422-0000-059, on desired location.
2)
With pump turned off and 0 PSI [kPa] on the lines, enter 0 for pressure calibration (cal pressure)
under Data Menu Key.
3)
When system is operating, system PSI [kPa] will be displayed when the or
key is
depressed.