25
15)
HIGH PWM OFFSET 253
Used to set the maximum desired RPM or hydraulic output of control valve.
a)
Display will show
HIGH PWM OFFSET 253
.
b)
Place product switch on MAN, boom switches and master switch ON. Hold INC/DEC switch
to increase. If motor exceeds desired RPM, decrease number by 10 and push INC again.
c)
Decrease the 253 number displayed until motor runs at desired maximum RPM, then enter
a number of 10 more.
d)
Momentarily depress to advance to LOW PWM OFFSET 1.
16)
LOW PWM OFFSET 1
Used to set the minimum desired RPM or hydraulic ouput of control valve. Used to set the zero point
or shut-off point of control valve.
a)
Display will show
LOW PWM OFFSET 1
.
b)
Place product switch on MAN, boom switches and master switch ON. Hold INC/DEC switch
to decrease until motor stops. Increase the number displaced until motor runs, then enter
a number of 10 less.
c)
Hold INC/DEC switch to decrease. If motor does not stop, lower offset number by 10 and
push DEC switch again.
d)
Momentarily depress to advance to PWM FREQUENCY 122.
17)
PWM FREQUENCY 122
a)
Display will show
PWM FREQUENCY 122
.
b)
Press . Enter the coil frequency of the PWM valve being used (i.e. 180 Hz). Press
, depress again.
c)
Momentarily depress to advance to TIER AUTO.
18)
TIER AUTO
a)
Display will show
TIER AUTO
.
b)
Depressing
momentarily changes the display between
TIER AUTO
and
TIER
MAN.
c)
Momentarily depress to advance to MINIMUM SYSTEM PRESSURE 20 if in TIER
AUTO or TIER A ONLY if in TIER MAN.
19)
MINIMUM SYSTEM PRESSURE 20
a)
Display will show
MINIMUM SYSTEM PRESSURE 20
.
b)
Press . Enter the minimum pressure for the system (i.e. 15 PSI). Press
, depress again.
c)
Momentarily depress to advance to MAXIMUM SYSTEM PRESSURE 60.