Contactor Fuses
Installation Instructions
Tools:
•
•
•
•
•
Standard Socket Wrench - 3/8” Drive
7mm Deep Well Socket - 3/8 Drive
8mm Deep Well Socket - 3/8” Drive
14mm Standard Socket - 3/8” Drive
7/16” Wrench
Parts:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
75A Fuse (x1)
100A Fuse (x2)
Single Fuse Holder (x1)
Double Fuse Holder (x1)
1/4”-20 Stainless Steel Nylock Nut (x3)
M4 Hex Nut (x4)
M4 Flat Washer (x4)
M4 Lock Washer (x4)
Black Rubber Cap (x4)
M6 Stainless Steel Flat Washer (x6)
M8 Hex Nut (x4)
M8 Flat Washer (x4)
M8 Lock Washer (x4)
M5x0.8 x 16mm Flanged Hex Head Cap Screw
4” Zip Tie (x4)
10” Zip Tie (x1)
Zip Tie Gun
(x4)
Installing the Contactor Fuses
IMPORTANT: Turn off power & remove key.
1.
Before beginning, ALL wires and jumpers
removed from both contactors.
should be
2.
Locate (2) 100A Fuses, the Double Fuse Holder, (2)
1/4-20 SS Nylock Nuts, and (4) M6 SS Flat Washers
(Fig. A).
Locate the J4 jumper from the red terminal block and
mount to Fuse B. Place an M6 flat washer over the fuse
stud followed by the jumper, another flat washer and
then a Nylock nut. Locate the red deck plug wire and
mount to Fuse A in the same manner (Fig. B). Tighten
the nuts using the 7/16” wrench. The jumpers should
be coming off the fuses at a 45° angle, pointed towards
the front of the unit.
Mount the Double Fuse Assembly to the large RH post
of the RH Contactor as shown in Fig. C. Place the red
wire from the square diode on next followed by an M8
flat washer, an M8 lock washer and an M8 nut. Tighten
using a 14mm socket and wrench. Ensure that red
diode wire is in line with the fuse holder.
Place the green square diode wire and one end of the
short contactor jumper wire on the large LH post of the
RH contactor. Secure with M8 flat washer, lock washer
and nut. Tighten with 14mm socket and wrench (Fig.
D).
3.
4.
5.
D e n v e r G l ob a l P r o duc t s 1 000 E as t P o we ll D r. | Li nc ol nt o n , N C 2 80 9 2 U. S . A
© 2 0 1 4 D en v e r Gl o b a l P ro du c t s | RATO A ll r i gh t s r es e rv e d .
RH Contactor
One End Of
Short Contactor
Jumper Wire
Green Wire
From Square
Diode
D
RH Contactor
Double Fuse
Assembly
Red Wire
From Square
Diode
C
J4 Jumper
Red Terminal
From
Block
Fuse B
Red Deck
Plug Wire
Fuse A
B
Double
Fuse
Holder
100A Fuse
(x2)
Fuse A
Fuse B
Stainless Steel
Hardware
A
Содержание MPV-7100
Страница 1: ...Raven 7100 Service Manual ...
Страница 2: ...12v Battery Exchange ...
Страница 4: ...12 Volt Relay Exchange ...
Страница 6: ...48 Volt Battery Pack Removal ...
Страница 8: ...Blade Motor Controllers ...
Страница 11: ...Carburetor Replacement ...
Страница 16: ...Contactor Fuse Replacement ...
Страница 21: ...Drive Motor Controller Replacement ...
Страница 27: ...Gas Gauge Check Replacement ...
Страница 30: ...Oil Separator Replacement ...
Страница 33: ...PCB Replacement ...