Troubleshooting: Diagnostic Trouble Code (DTC) List
67
TROUBLESHOOTING
523192
.13
Sparge pressure transducer not
calibrated
1. Refer to the “Tools Menu Settings Definitions”
on page 22 for assistance with pressure
transducer calibration.
.14
New injection pump detected
1. A new injection pump was detected.
.15
Injection pump lost
communication
1. Verify the LED’s on the injection pump are on.
2. Check the CAN connections of the injection
device.
3. Connect the Raven Service Tool to the
ISOBUS and verify communication.
523193
.16
High system efficiency
1. Check the plumbing system for leaks.
2. Check the pressure transducer calibration.
3. Check the Flowmeter Calibration value.
4. Verify the fencerow outputs are not active.
5. Check the NCV’s for debris or seal for wear.
.18
Low system efficiency
1. Check the pressure transducer calibration.
2. Check the Flowmeter Calibration value.
3. Check the NCV’s for debris or seal
deformation.
523520
.31
Invalid flowmeter calibration
1. Enter a valid flowmeter calibration value.
523906
.17
Equipment speed below the
speed range (single nozzle)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 44 and Hawkeye Lower Home
Screen section on page 47 for assistance with
the information provided on the home
screen.
523907
.17
Equipment speed below the
speed range (multiple nozzles)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen.
523908
.15
Equipment speed above the
speed range (single nozzle)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen.
523909
.15
Equipment speed above the
speed range (multiple nozzles)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 44 and Hawkeye Lower Home
Screen section on page 47 for assistance with
the information provided on the home
screen.
523910
.31
Nozzle power/temperature error
(single)
1. Check for clogs in valve or associated
plumbing that may be preventing liquid flow
through the valve.
523911
.31
Nozzle power/temperature error
(multiple)
1. Check for restrictions in valves or associated
plumbing that may be preventing liquid flow
through the valve.
Code ID
Description
Recommended Actions
Содержание Hawkeye
Страница 1: ...ISO Product Controller II and Hawkeye Operation Manual P N 016 0171 584 H 01 19 E32470 Copyright 2019 ...
Страница 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual ...
Страница 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer ...
Страница 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN ...
Страница 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling ...
Страница 111: ...P N 016 0171 584 H 101 ...
Страница 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 122: ...APPENDIX G 112 ISO Product Controller II and Hawkeye Operation Manual FIGURE 1 Hawkeye Screen Flow Tools Menu Softkey ...
Страница 125: ...P N 016 0171 584 H 115 FIGURE 4 Hawkeye Screen Flow Tally Registers and Diagnostics Menu Softkeys ...
Страница 127: ...P N 016 0171 584 H 117 FIGURE 6 Hawkeye Injection Screen Flow Product Setup Alarms and System Information ...
Страница 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual ...