APPENDIX
A
: Overview
73
APPENDIX A
AVOIDING SKIPS WITH
HAWKEYE NOZZLE CONTROL
SYSTEM
OVERVIEW
The Hawkeye nozzle control system is designed to pulse each spray tip using an alternating pattern across the
implement width. This alternating nozzle spray pattern relies upon an overlapping spray tip pattern and droplet
dispersion to achieve complete and even coverage during field applications.
RECOMMENDATIONS FOR HAWKEYE NOZZLE CONTROL OPERATION
Maintain the following application system conditions will help to ensure consistent, even coverage during field
applications using the Hawkeye nozzle control system:
1. Use the appropriate tip size for the desired droplet size, application speeds, target rates, and system pressures.
Refer to the tables in the
Tip Selection and Application Speed Guide
section on page 77.
2. Use wide-angle spray tips and appropriate spray tip height to achieve approximately 150% pattern overlap.
a. When using 80° spray tips:
•
20” spacing have a minimum spray tip height of 36” (91.4 cm)
•
15” spacing have a minimum spray tip height of 27” (68.6 cm)
•
10” spacing have a minimum spray tip height of 18” (45.7 cm)
b. When using 110° spray tips:
•
20” spacing have a minimum spray tip height of 21” (53.3 cm)
•
15” spacing have a minimum spray tip height of 16” (40.6 cm)
•
10” spacing have a minimum spray tip height of 10” (25.4 cm)
3. Maintain a system pressure sufficient to fully develop the intended tip spray pattern.
4. Avoid nozzle control valve duty cycles below 25%.
a. Stay within the displayed speed range for a selected tip size, application rate, and pressure.
b. Avoid application speeds in the bottom 1/3 of the recommended speed range.
c. Avoid target flow rates in the bottom 1/3 of the recommended application rate range for each spray tip.
d. When turn compensation is active, make gradual turns to avoid operating the NCV’s at their limits.
5. Target application speeds, tip sizes, and operating pressures so the NCV’s operate at approximately 70% +/-
10% duty cycle on average for the desired spray droplet size.
Содержание Hawkeye
Страница 1: ...ISO Product Controller II and Hawkeye Operation Manual P N 016 0171 584 H 01 19 E32470 Copyright 2019 ...
Страница 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual ...
Страница 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer ...
Страница 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN ...
Страница 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling ...
Страница 111: ...P N 016 0171 584 H 101 ...
Страница 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 122: ...APPENDIX G 112 ISO Product Controller II and Hawkeye Operation Manual FIGURE 1 Hawkeye Screen Flow Tools Menu Softkey ...
Страница 125: ...P N 016 0171 584 H 115 FIGURE 4 Hawkeye Screen Flow Tally Registers and Diagnostics Menu Softkeys ...
Страница 127: ...P N 016 0171 584 H 117 FIGURE 6 Hawkeye Injection Screen Flow Product Setup Alarms and System Information ...
Страница 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual ...