5
P/N 016-0171-584-H
45
OPERATION
FIGURE 3. Hawkeye with Injection Upper Home Screen
AREA APPLIED
The field area applied tally is displayed in the application area for quick reference of the area covered during the
current operation.
TARGET RATE
Select the target value to enter the desired target rate for product application (e.g. 15 gallons per acre [140 liters
per hectare]).
RATE GAUGE
The rate gauge provides a visual representation of the actual application rate and displays the allowable rate
deadband during field applications.
NOTE:
Refer to the System Settings Tab - Alarm section on page 30 for assistance with setting the rate gauge
deadband or the Flow Meter Maintenance section on page 99 for additional assistance with
calibrating the flow meter.
If the Use Gauges to Toggle Quick Key Selection option is enabled, touch the rate gauge to toggle between the
rate preset and rate ± bump buttons in the softkeys area. Refer to the System Settings Tab - Presets section for
additional assistance with the rate and pressure presets options.
APPLICATION MODE
The application mode indicator displays the selected mode for product control. Select the “Auto/Manual” button
to toggle the application mode between automatic (Auto) and manual (Manual). The active mode will display.
FIGURE 4. Manual/Auto Toggle
Actual Rate
Gauge/Rate
Toggle
Target Rate
Current Speed
Selected Injection
Product On/Off
Selected Product
Auto/Manual
Carrier
Pressure
Injection Pressure
Gauge
Selected Injection
Pump Efficiency
Applied Acres
Содержание Hawkeye
Страница 1: ...ISO Product Controller II and Hawkeye Operation Manual P N 016 0171 584 H 01 19 E32470 Copyright 2019 ...
Страница 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual ...
Страница 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer ...
Страница 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN ...
Страница 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling ...
Страница 111: ...P N 016 0171 584 H 101 ...
Страница 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 122: ...APPENDIX G 112 ISO Product Controller II and Hawkeye Operation Manual FIGURE 1 Hawkeye Screen Flow Tools Menu Softkey ...
Страница 125: ...P N 016 0171 584 H 115 FIGURE 4 Hawkeye Screen Flow Tally Registers and Diagnostics Menu Softkeys ...
Страница 127: ...P N 016 0171 584 H 117 FIGURE 6 Hawkeye Injection Screen Flow Product Setup Alarms and System Information ...
Страница 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual ...
Страница 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual ...