15
d)
After desired speed is set, depress
. HIGH OFFSET is now set.
e)
Depress
to advance to SPINNER LOW OFFSET.
2)
SPINNER LOW OFFSET
a)
GRAN display will show "oFS". LIQ display will show "SpLo". DATA display
will show "2".
b)
Depress
.
c)
Depress
and spinner will stop rotating. Depress and hold
until the spinner begins to rotate. Depress
and
until
spinner is rotating at the minimum speed desired.
d)
After desired speed is set, depress
. LOW OFFSET is now set.
e)
Depress
to advance to GRANULAR HIGH OFFSET.
3)
GRANULAR HIGH OFFSET
When setting the Granular offsets the truck must be running and associated
hydraulics turned on. Place POWER switch on GRAN, SPINNER knob on "1",
RATE knob on "M", and MASTER switch ON.
a)
GRAN display will show "oFS". LIQ display will show "Grhi". DATA display
will show "254".
b)
Depress
.
c)
Depress
to start the auger/bed turning. The RPM's of the granular
motor/shaft and "oFS" will alternately be displayed in the GRAN display.
While auger/bed is turning, depress and hold
until the RPM's begin
to decrease. Depress
to slowly increase RPM's until the maximum
RPM is noticed, then increase offset value displayed in the DATA display
by an additional 10.
Содержание DCS 700
Страница 1: ...DCS 700 INSTALLATION AND SERVICE MANUAL ...
Страница 3: ......
Страница 4: ...Manual Rev B DCS 700 063 0171 711 7 99 016 0159 775 ...