13
6)
Enter the following values in
. Depress
to advance through the
GRAN METER CAL menu.
DISPLAY SCREENS
GRAN
LIQ
DATA
PROCEDURE
SAnd
0
Enter an initial value of "0".
SALt
0
Enter an initial value of "0".
Prd1
0
Enter an initial value of "0".
Prd2
0
Enter an initial value of "0".
The actual GRAN METER CAL values will be obtained after initial programming is
completed. Refer to section "CALCULATING GRAN METER CAL" for further
instructions.
7)
Enter the calibration number from flow meter tag in
. If the pre-wet
system is not controlled by the console (open loop system) enter "0".
8)
Depress
. This console contains a factory default value of "73". Refer
to Appendix 3 page 40 to adjust this value if necessary.
9)
Depress
. This console contains a factory default value of "73". Refer
to Appendix 3 page 40 to adjust this value if necessary. If pre-wet system is
not controlled by the console (open loop system) enter "0".
10)
Enter the following values in
.
DISPLAY SCREENS
GRAN
LIQ
DATA
PROCEDURE
SAnd
r-01
0
Enter the desired granular application rate
(lbs/mile) [kg/km].
Depress the
and
keys to advance through rates 1-10 ("r-01" through
"r-10") for Sand.
NOTE: Salt, Prd1, and Prd2 application rates will default to the Sand application
rates during initial calibration. These application rates can be changed
after initial calibration is completed.