19
6)
Place MASTER switch to OFF.
7)
Weigh the truck and record the weight as weight #2.
8)
Depress
. The GRAN display will show "CAL". The LIQ display will show
"Grto". The DATA display will show "0".
9)
Calculate and enter in the total pounds (kg) of material unloaded.
EXAMPLE:
Weight #1 = 32590
Weight #2 = -31450
Total unloaded
1140
Enter 1140 pounds (kg) as "Grto"
10)
After total pounds are entered the DATA display will show "0".
11)
Depress
and the DATA display will show the new Meter Cal number for that
product.
4.
VERIFYING "GRAN METER CAL"
Factors which can affect the product GRAN METER CAL numbers are the product
particle size, density, temperature, and humidity. Always calibrate the material
you have purchased. Complete INITIAL CONSOLE PROGRAMMING before proceeding with
this procedure. The GRAN METER CAL value is verified using the following
procedure:
1)
Use a pre-weighed box to capture the material as it is metered out.
2)
Verify calculated GRAN METER CAL value is entered into
.
3)
With the MASTER switch in the OFF position, place RATE knob to "M".
4)
Depress
. The GRAN display will show "SAnd". The LIQ display will show "dAY".
The DATA display will show the volume. Depress
to advance the GRAN display
to Salt, Prd1, or Prd2. Enter a "0" in this key.
5)
Place MASTER switch to SEL and verify the correct product is displayed or depress
and
to select the appropriate product. Place MASTER switch to ON
to begin unloading material. Use the manual INC/DEC switch to adjust the auger/
bed speed. During verification test, monitor material to ensure bridging or
tunneling does not occur.