30
b)
Enter the current day of the month.
c)
Depress
to advance to YEAR.
YEAR
a)
GRAN display will show "dAtE". LIQ display will show "YEAr". The DATA
display will show "00".
b)
Enter the current year.
c)
Depress
to advance to POWER DOWN.
POWER DOWN
a)
If the Console is not used for 30 days, it will go into a power down (low
power) mode of operation. In this mode, all data is retained, but the time
of day clock will reset to 0:00. The delay time is initially set at 30
days; but can be changed by the user.
b)
GRAN display will show "dAtE". LIQ display will show "P dn". The DATA
display will show "30".
c)
To change the delay time enter a new number from 0 to 200 days.
d)
Depress
to advance to TIME.
e)
Depress
to advance to the FLOW RATE SCREENS.
FLOW RATE SCREENS
GRANULAR VOLUME/MINUTE
a)
GRAN display will show "Fr". LIQ display will show "FLGr". The DATA display
will show the volume per minute of granular material.
b)
Depress
to advance to PRE-WET VOLUME/MINUTE.
PRE-WET VOLUME/MINUTE
a)
GRAN display will show "Fr". LIQ display will show "FLPr". The DATA display
will show the volume per minute of pre-wet liquid.
b)
Depress
to advance to GRANULAR LOW LIMIT FLOW ALARM.
GRANULAR LOW LIMIT FLOW ALARM
a)
If the actual volume per minute falls below the set limit, the valve
stops closing, an alarm sounds and the GRAN display flashes "-LL-".
b)
GRAN display will show "Fr". LIQ display will show "LLGr". DATA
display will show ".0".
c)
Enter the low limit of the system (lb/min) [kg/min].