25
8.
AUTOMATIC RATE +/-
This feature allows an increment to be set at which flow may be increased or
decreased while in automatic operation (rates 1-10). To select RATE +/- depress
for granular or
for liquid until DATA display flashes. To enter a
value depress
, increment value, and
. When using this feature the
preprogrammed application rates will be changed accordingly.
EXAMPLE:
If granular rate is to change by "10":
Enter a value of 10 for RATE +/-. When in RATES 1-10, each time the MANUAL
INC/DEC switch is positioned to INC, the RATE for that product will increase
by "10". Likewise, when positioned to DEC, the RATE will decrease by "10".
When POWER switch is on GRAN it increases or decreases granular rates, when
on GR/LI, it increases or decreases liquid rates.
9.
LOW TANK ALARM
This feature will sound the alarm when the granular or liquid volume drops below
an entered value. If the granular or liquid volume falls below the low tank value
entered, the alarm will sound 8 beeps every 15 seconds and depending on which
tank is low the GRAN or LIQ display screen will flash "LEul". The alarm will
stop when a value equal to or greater than the Low Tank Alarm value is entered
into VOLUME/GRAN, VOLUME/LIQ or the MASTER switch is turned OFF. Entering "0"
into Low Tank Alarm disables the alarm.
a)
Depress
for granular or
for liquid until the DATA display
flashes.
b)
To enter a value, depress
, LOW TANK ALARM value, and
.
NOTE: Go to DATA MENU to silence audible alarm.
10. LOW LIMIT FLOW ALARM
The low limit feature allows the operator to set a minimum vol/min in the console
for the system to maintain regardless of vehicle speed. If the actual vol/min
reaches the set minimum vol/min, the control valve will stop closing to ensure
the low limit flow is maintained. When this occurs the console will be over
applying material until the actual vol/min exceeds the low limit flow value. An
audible and visual alarm will alert the operator. The visual alarm will display
"-LL-" in the GRAN or LIQ display screen. Depress
until the GRAN display
shows "Fr". LIQ display will show "FLGr". DATA display will show ".0". To advance
through the categories depress
.