40
0472-M021-1
BESEITIGUNG
Auswechseln
Auswechseln
Kontrollieren
Abwarten bis Thermosonde wieder ein-
schaltet
Normen beachten (Kap. 1)
Nachprüfen
STÖRUNG
Kein Funktionieren
Aufwärtsfahrt wird nicht beendet
URSACHE
Hauptsicherungen unterbrochen
Transformator-Sicherung unterbrochen
Störung in der Elektroanlage
Thermosonde des Motors hat abgeschaltet
Last liegt über der Nominaltragkraft
Erforderliche Spannung zu niedrig
INTERVENTO
Sostituire
Sostituire
Controllare
Attendere il riarmo
Attenersi alle norme (cap. 1)
Verifi care
Sostituire
Registrare o sostituire
Sostituire
Sostituire guaina e cavetto
Togliere e procedere alla corretta regi-
strazione del meccanismo di riallineo
(par.6.6)
INCONVENIENTE
Nessun funzionamento
Non completa la corsa di sollevamento
I carrelli salgono solo per 300 mm con
successivo disinserimento della sonda
termica.
Corsa sollevamento irregolare
Blocco meccanico
Il sollevatore non riallinea in discesa
(colonna opposta più alta) od in salita
(colonna opposta più bassa)
REMEDY
Replace
Replace
Check the electric installation
Wait for automatic reset
Follow instructions (Chap. 1)
Check
Replace main nuts
Adjust or replace belts
Replace limit switch
Replace sheath and cable
Remove and adjust the realignment
mechanism correctly (par. 6.6)
8. INCONVENIENTI
Qui di seguito sono elencati alcuni degli inconvenienti possibili durante il funzionamento del Ponte. La Ravaglioli declina ogni responsa-
bilità per danni dovuti a persone, animali e cose, per intervento da parte di personale non autorizzato. Pertanto al verifi carsi del guasto
si raccomanda di contattare tempestivamente l’assistenza tecnica in modo da ricevere le indicazioni per poter compiere operazioni e/o
regolazioni in condizioni di massima sicurezza, evitando il rischio di causare danni a persone, animali e cose.
E’ necessario l’intervento dell’assistenza tecnica. Vietato eseguire intervento.
Posizionare sullo "0" e lucchettare l'interruttore generale in caso di emergenza e/o manutenzione al sollevatore
Turn to 0 and padlock the main switch in case of emergency and/or maintenance to the lift
Den Hauptschalter bei Not-Aus und/oder Wartung der Hebebühnen auf “0” positionieren und verriegeln.
8. TROUBLESHOOTING
Certain problems which may arise while using the lift are listed below. Ravaglioli cannot accept any liability for injury to people or ani-
mals and damage to things caused by unauthorised staff using the equipment. In the event of faults, you are advised to contact the
technical service department in good time to receive advice about how to carry out work and/or adjustments in maximum safety condi-
tions, thus avoiding the risk of injury to people or animals and damage to things.
Technical service staff are required. Intervention by others prohibited.
PROBLEM
Lift does not work
Lifting travel is not completed
Lift rises 300 mm, then heat probe discon-
nects
Irregular lifting
Mechanical block
The lift does not realign during down-stro-
ke (opposite column is higher) or up-stroke
(opposite column is lower)
POSSIBLE CAUSE
Main safety fuses burnt out
Trasformer fuse burnt out
Power failure
Heat probe disconnected
Load exceeds rated lifting capacity
Voltage of the mains is too low
Mechanical stop due to total wear of main
nuts
Drive belts are slipping
Limit switch damaged
friction of cable into the sheath is too high
because sheath is squashed or damaged.
The problem is characterized by differences
of “A” value –as specifi ed under par. 6.6-
which are higher than 3-4 mm between up-
stroke and down-stroke.
The spacer inhibiting the realignment
system has NOT been removed
8. BETRIEBSSTÖRUNGEN
Nachstehend einige der Betriebsstörungen, die während der Bedienung der Hebebühne auftreten könnten. Ravaglioli übernimmt in
keinem Fall die Haftung für eventuelle durch Eingriffe seitens nicht autorisiertem Personal verursachte Schäden an Personen, Tieren
oder Sachen. Bei Betriebsstörungen unverzüglich den technischen Kundendienst zu Rate ziehen, damit Anweisungen zur Ausführung
der Eingriffe und/oder Einstellungen unter Berücksichtigung der notwendigen Sicherheitsmassnahmen, damit weder für Personen,
Tiere noch Sachen Gefahr besteht, erteilt werden können.
Muss durch den technischen Kundendienst ausgeführt werden. Eingriff verboten.
CAUSA
Fusibili di protezione generale interrotti
Fusibili e trsformatore interrotto
Guasto all’impianto elettrico
Disinserimento sonda termica motore
Carico eccedente la portata nominale
Tensione rete troppo bassa
Blocco meccanico in atto per usura chioc-
ciole portanti
Slittamento cinghie di trasmissione
Finecorsa danneggiato
Troppo attrito del cavetto nella guaina a
causa di schiacciamenti o danneggiamenti
della stessa. Il problema è evidenziato da
differenze di quota “A” parag. 6.6 superiori
ai 3 – 4 mm tra la manovra di salita e quella
di discesa.
NON è stato rimosso il distanziale che inibi-
sce il sistema di riallineo
8
Содержание KPX337 WBMW
Страница 12: ...12 0472 M021 1 3200 Kg 2 P1 P2 Min 1200 mm P1 P2...
Страница 14: ...14 0472 M021 1 3 331 580 1212 2372 2400 max 101 100 2639 5 3868 3100 3025 min 78 1200 1800 H 100 362 810 1980...
Страница 16: ...16 0472 M021 1 3 A...
Страница 22: ...22 0472 M021 1 1 4000 1500 2500 KPX 337 1900 Kg 1 500 000 Kgmm 300 000 Kgmm 6 P Mx My...
Страница 26: ...26 0472 M021 1 6 2 4 3 D B A C...
Страница 32: ...32 0472 M021 1 10 8 9 6 13 mm A 36 FC1 FC2 B F D E C 2 cm...
Страница 34: ...34 0472 M021 1 6 13 14 11 12 A NO A A...
Страница 38: ...38 0472 M021 1 15 16 7 A A 02 1...
Страница 42: ...42 0472 M021 1 18 19 2 mm 9 17 a b max mm 10 min mm 2...