General commissioning (all machine types)
83
8
AXISAXIS
Figure 8.27:
Layout of the collecting vessels
Make sure that the collecting vessels are placed on level ground. Collecting
vessels set at an angle can cause measuring errors (see image above).
Carry out the calibration test (see chapter B.6 of the corresponding machine
type).
Adjust and fix the metering slides on the right and left-hand side (see chapter
B.4 of the corresponding machine type).
Run the spreading test with the openings set as calculated for the job:
Forward speed:
3 to 4 km/h
.
Open the metering slide
10 m in front of
the collecting vessels.
Close the metering slides approx.
30 m behind
the collecting vessels.
NOTICE
If the quantity collected in the collecting vessels is insufficient, repeat the run.
Do not change the adjustment of the metering slides.