Operation AXIS ISOBUS
4
42
Operating mode selection
1.
Switch on the AXIS ISOBUS machine control unit.
2.
Open the
Machine settings > AUTO/MAN mode
menu.
3.
Select the desired menu item from the list.
4.
Press
OK
.
5.
Follow the instructions on the screen.
Important information on the use of operating modes for the spreading oper-
ation is provided in chapter
5: Spreading operation with the machine control
Automatic mode with automatic weighing (AUTO km/h + AUTO kg)
1.
Select operating mode AUTO km/h + AUTO kg
2.
Press
OK
.
The
Weigh quantity
window is displayed.
3. Case a: Refill
The flow factor setting is retained.
The left fertiliser quantity is increased by the refill quantity.
Case b: New fertiliser
The flow factor is reset to 1. If necessary, the required flow factor value
can be entered subsequently. Refer to chapter
4.
Select the desired type of filling.
The machine control unit switches to the operating screen.
NOTICE
We recommend displaying the flow factor in the operating screen. This way, the
mass flow control can be monitored during spreading. Refer to
chapter
and chapter
.
n
CAUTION
Cancelling the weighing function may lead to incorrect meter-
ing
The
ESC
button must not be pressed. This may lead to serious
errors in application rate/metering.
To confirm the weighing function, always select the type of
filling.
Содержание AXIS ISOBUS
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 22: ...Structure and function 2 16...
Страница 78: ...Operation AXIS ISOBUS 4 72...
Страница 98: ...Spreading operation with the machine control unit AXIS ISOBUS 5 92...
Страница 104: ...Special equipment 7 98...
Страница 108: ...Index D...
Страница 110: ......