Operation AXIS ISOBUS
31
4
Running the calibration test:
5.
Press
Start/Stop
.
The metering slide of the previously selected spreading side opens and
the calibration test is started.
6.
Press
Start/Stop
again.
The calibration is completed.
The metering slider closes.
The third calibration page is displayed.
n
WARNING
Risk of injury during calibration
Rotating machine components and ejected fertiliser may cause
injury.
Before starting
the calibration, ensure that all precondi-
tions have been met.
Follow the
Calibration
chapter in the machine’s operating
manual.
NOTICE
The calibration test can be stopped at any time by pressing the
ESC
key. The
metering slide is closed and the
Fertiliser settings
menu is displayed.
NOTICE
The calibration time is not relevant for the accuracy of the results. However,
a
minimum of 20 kg
should be calibrated.