Spreading operation with the machine control unit AXIS ISOBUS
75
5
If the status of the TELIMAT unit cannot be detected for more than 5 seconds,
alarm message 14 will be displayed. Refer to chapter
.
Figure 5.2:
TELIMAT alarm message display
TELIMAT with electrical remote control
By pressing the
TELIMAT
function key, the electrical TELIMAT moves to the lim-
ited border spreading position. During configuration, a
? symbol
is displayed at
the machine control unit and disappears once the working position has been
reached. Additional sensor monitoring of the TELIMAT position is not necessary
as actuator monitoring is integrated.
If the TELIMAT is blocked, alarm 23 is displayed. Refer to chapter
n
CAUTION
Risk of injury due to automatic TELIMAT adjustment
After pressing the
TELIMAT
function key, the unit automatically
moves to the limited border spreading position by using an actua-
tor. This may cause injury and property damages.
Before pressing the
T key
, make sure that no one is in the
hazard zone of the machine.