Application rate
In this menu, you can enter the desired target value for the application rate.
Entering the application rate:
1.
Open the
Fertiliser settings > Appl. rate (kg/ha)
menu.
The
currently applied
application rate is displayed.
2.
Enter the new value in the input field.
3.
Press
OK
.
The new value is saved in the machine control unit.
You can also enter or adjust the application rate directly via the operating screen.
1.
Press the Application rate [1] button on the touch screen.
The number input window opens.
Bound. sprd. type
Selection list:
Full border
Limited
Selection with
Arrow keys
Confirmation
with the
Enter
key
Mounting height
Input in cm
Selection list: 0/6, 40/40, 50/50, 60/60,
70/70, 70/76
Fertilisation method
Selection list:
Normal
Late
Selection with
Arrow keys
.
Confirm by
pressing the
Enter key
.
Manufacturer
Fertiliser manufacturer input.
Composition
Percentage content of chemical com-
position
Calculate OptiPoint
Input of the GPS-Control parameters
Turn-on distance (m) Turn-on distance display
Turn-off distance (m) Turn-off distance display
GPS control informa-
tion
Display of information of the GPS con-
trol parameters
Fertiliser chart
Management of fertiliser charts
Sub-menu
Meaning/possible values
Description
Содержание AXIS ISOBUS
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 22: ...Structure and function 2 16...
Страница 78: ...Operation AXIS ISOBUS 4 72...
Страница 98: ...Spreading operation with the machine control unit AXIS ISOBUS 5 92...
Страница 104: ...Special equipment 7 98...
Страница 108: ...Index D...
Страница 110: ......