Alarm messages and possible causes
93
6
6
Alarm messages and possible causes
Various alarm messages can be displayed on the AXIS ISOBUS machine control
unit display.
6.1
Alarm message meanings
No. Message on display
Meaning
Possible cause
1
Fault in dosing system. Stop! The metering system actuator cannot reach
the target value.
Blockage
No position feedback
2
Maximum outlet reached!
Speed or application rate too
high
Metering slider alarm
The maximum metering opening is
reached.
The set application rate (+/- quantity) ex-
ceeds the maximum metering opening.
3
Flow factor is outside limits.
The flow factor must be within the range be-
tween
0.20 and 1.90
The newly calculated or entered flow
factor is outside the range.
4
Hopper left empty.
The left level sensor reports "empty".
The left hopper is empty.
5
Hopper right empty.
The right level sensor reports "empty".
The right hopper is empty.
7
Data will be deleted!
Delete = START
Cancel = ESC
Safety alarm to prevent the unintentional
deletion of data.
8
Min. quantity (150 kg) not
achieved, old factor valid.
Flow factor calculation not possible.
The
AUTO km/h + Stat. kg
operating
mode is selected.
The application rate is too low to calcu-
late the new flow factor when the re-
maining quantity is weighed.
The old flow factor is maintained.
11 Flow factor
Min. setting = 0.40
Max. setting = 1.90
Reference to the value range of the
flow
factor
.
Entered value is not permitted.
14 Error by setting TELIMAT.
Alarm for the TELIMAT sensor.
This error message is displayed if the TELI-
MAT status is not detected for more than 5
seconds.
Содержание AXIS ISOBUS
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 22: ...Structure and function 2 16...
Страница 78: ...Operation AXIS ISOBUS 4 72...
Страница 98: ...Spreading operation with the machine control unit AXIS ISOBUS 5 92...
Страница 104: ...Special equipment 7 98...
Страница 108: ...Index D...
Страница 110: ......