Maintenance and service
101
9
9.5
Checking the agitator for wear
9.5.1
Dismounting the agitator
The agitator is fixed with a bayonet lock.
1.
Open maintenance cover.
2.
Turn the agitator clockwise
until it reaches the stop.
3.
Lift the agitator out in an up-
wards direction.
Figure 9.4:
Dismounting the agitator
NOTICE
Install the agitator in reverse order. Ensure that the bayonet lock of the agitator
engages safely.
Grease the bayonet lock and the agitator.