background image

C

HAPTER 

2:

 

A

CCESSING 

CC-SG 

 

 

 

Accessing a Serial Interface for the First Time 

To access a remote node that is connected via a serial interface, click the Nodes tab and select the 
interface. If the node is configured for a console application, a Security Warning appears, 
indicating that the console applet is a signed applet from Raritan Systems. Click 

Yes

 and the 

console appears.  

Warning: The security warning display (appearing in IE only) appears the first 
time the user connects to a serial interface. Click Yes when this display 
appears; if you click No, the console application does not launch and you must 
exit CC–SG, close the browser, re-launch the browser, and connect to CC–SG 
again.  

For additional details about RaritanConsole operation, please refer to Raritan’s 

RaritanConsole 

User Guide

.  

When a custom application is associated with a KVM or serial interface, selecting that interface 
launches the associated application. Raritan Remote Control and RaritanConsole are examples of 
custom applications that can be integrated into CC-SG.  

 

Содержание CC-SG

Страница 1: ...CommandCenter Secure Gateway CC SG User Guide Release 3 1 Copyright 2007 Raritan Inc CC 0K E January 2007 255 80 3100...

Страница 2: ...This page intentionally left blank...

Страница 3: ...e FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy an...

Страница 4: ...require Rack Mounting please follow these precautions Operation temperature in a closed rack environment may be greater than room temperature Do not exceed the rated maximum ambient temperature of th...

Страница 5: ...Managing Power to an IPMI Server Node 19 Disconnect from a Node 20 Node Views 20 Tree View 20 Custom View 21 Node Sorting Options 23 Power Control for Nodes 24 Single Interface Power Control 24 Single...

Страница 6: ...a custom view 43 Search for Nodes 43 Supported Wildcards 44 Node Chat 44 My Profile 44 Change Your Password 44 Change Your Email Address 45 Set Default Node List 45 Chapter 5 Generating Reports 47 Ac...

Страница 7: ...19 Nodes Tree in Standard Tree View 20 Figure 20 Custom View Screen 21 Figure 21 Add Custom View Window 22 Figure 22 Edit Custom View Window 22 Figure 23 Delete Custom View Window 23 Figure 24 Single...

Страница 8: ......

Страница 9: ...an be managed by CC SG Targets of an iLO RILOE device are powered on off and recycled directly In band Access using the TCP IP network to correct or troubleshoot a node in your network You can access...

Страница 10: ...2 COMMANDCENTER SECURE GATEWAY USER GUIDE This page intentionally left blank...

Страница 11: ...re You Begin CC SG is accessed via a web browser from a user s PC Please verify the following JRE The browser must have the correct version of Java Runtime Environment installed for full functionality...

Страница 12: ...er you want to download the correct JRE version from the CC SG server if available download it from the Sun Microsystems web site or continue with the incorrect version and then click OK 2 With the co...

Страница 13: ...cation window appears The menu bar and tool bar which contain commands for operating CC SG are at the top of the screen The Nodes tab displays the Nodes selection tree The central panel is where opera...

Страница 14: ...e CC SG https IP address For example https 10 0 3 30 The login screen appears Figure 3 Access Client Login Screen 2 If the CC SG Administrator has enabled the Restricted Service Agreement read the agr...

Страница 15: ...s to run your computer may become unresponsive Do you want to abort the script This warning message occurs when a script is taking longer than the default time to run Please click No in the warning me...

Страница 16: ...unch the CC SG client An address specification window appears Figure 5 IP Specification Window 3 Type the IP address of the CC SG unit you want to access in the IP to connect field and then click Star...

Страница 17: ...earing in IE only appears the first time the user connects to a serial interface Click Yes when this display appears if you click No the console application does not launch and you must exit CC SG clo...

Страница 18: ...ing Options and then click By Node Name or By Node Status 2 Quick Commands toolbar This toolbar offers some shortcut buttons for executing common commands rapidly 3 Operation menu bar These menus cont...

Страница 19: ...ten nodes you have most recently accessed Click a node to open the Node tab The Node tab contains the Node profile with details on the selected node You can also connect to an interface chat with othe...

Страница 20: ...atus Nodes arranged by status are sorted alphabetically within their availability grouping To switch between arranging methods right click on the tree click Node Sorting Options then click Sort By Nod...

Страница 21: ...KX 1 4 s interface displays the Connected Availability category the interface may be either Connected or Busy Connect to Nodes Once interfaces have been configured for each node you are ready to conne...

Страница 22: ...s in a new window Use the application to manage the node Figure 10 Raritan Serial Console 5 When you are finished using RSC to manage the node on the RSC Emulator menu click Exit 6 Repeat the steps in...

Страница 23: ...file Screen Out of Band KVM Interface 2 In the Node Profile screen all configured interfaces display in the Interfaces section 3 In the Name column click the hyperlink of the Out of Band KVM interface...

Страница 24: ...ng to a node using MPC the saved settings are applied to the MPC session 6 When you are finished using RRC or MPC to manage the node from the Connection menu click Exit 7 Repeat the steps in this sect...

Страница 25: ...en all configured interfaces display in the Interfaces section 3 In the Name column click the hyperlink of the In Band KVM interface you want to use to connect to the node 4 The Remote Console applet...

Страница 26: ...LO RILOE enabled node with an in band iLO RILOE power control interface Figure 16 Node Profile Screen In Band Power Interface 2 In the Node Profile screen all configured interfaces display in the Inte...

Страница 27: ...Profile screen appears 2 In the Node Profile screen all configured interfaces display in the Interfaces section 3 In the Name column click the hyperlink of the power control IPMI interface you want to...

Страница 28: ...odes are arranged into a standard Tree View The standard Tree View displays nodes in alphabetical order If you want nodes to display in a different order you can create a Custom Views Custom Views all...

Страница 29: ...Custom View that displays nodes first by their location then by which rack they are installed in Select a Custom View 1 On the Nodes menu click Change View and then click Custom View The Custom View s...

Страница 30: ...om View Details list into the order in which you would like each category to display in the Nodes tab Select a category and then click Up or Down to move the categories into the desired sequence 7 If...

Страница 31: ...iew has been updated 10 If you want to use the edited custom view click Set Current to display the Nodes tree by the categories specified in the custom view 11 Repeat the steps in this section to edit...

Страница 32: ...ycle Graceful Shutdown The Power Control screen appears Figure 24 Single Interface Power Control 2 The selected interface name displays in the Selected list The power operation you selected on the rig...

Страница 33: ...ist into the order in which you would like CC SG to perform the power operation Select an interface in the Selected list and then click the up and down arrows to move the interfaces into the desired s...

Страница 34: ...es to the Selected list If you must remove an interface select the interface in the Selected list and then click Remove 5 You must put the interfaces in the Selected list into the order in which you w...

Страница 35: ...on to join the chat session The chat session window will appear with the message fields on the left and a list of users in the chat session on the right 3 Type a message in the new message lower left...

Страница 36: ...our search terms as you type There is no Search button You cannot use wildcards with this search type You can set your search preference in your CC SG profile To access your profile click My Profile o...

Страница 37: ...r additional information on search preferences WILDCARD DESCRIPTION Indicates any character Indicates a character in range Indicates zero or more characters Examples are as follows EXAMPLE DESCRIPTION...

Страница 38: ...eway menu click My Profile The Change My Profile screen appears Figure 29 My Profile Screen 2 Check the Change Password checkbox to activate the change password fields 3 Type your current password in...

Страница 39: ...use in its screens 3 Click OK Set Search Preference CC SG offers two search types Filter by Search Results and Find Matching String You can set your search preference in My Profile Filter by Search Re...

Страница 40: ...s Each node has a Node details screen which lists all associated interfaces to which you have access Click a node in one of the node lists in the left panel All Nodes Favorites and Recent to open the...

Страница 41: ...screen all configured interfaces display in the Interface section 3 In the Name column click the hyperlink of the serial interface you want to use to connect to the node 4 The RSC application launche...

Страница 42: ...e Profile Screen Out of Band KVM Interface 2 In the Node details screen all configured interfaces display in the Interface section 3 In the Name column click the hyperlink of the KVM interface you wan...

Страница 43: ...ng to a port using MPC the saved settings are applied to the MPC session 6 When you are finished using RRC or MPC to manage the node from the Connection menu click Exit 7 Repeat the steps in this sect...

Страница 44: ...lay in the Interface section 3 In the Name column click the hyperlink of the KVM interface you want to use to connect to the node 4 The HP Remote Console applet launches When the applet loads you have...

Страница 45: ...ower for in one of the node lists in the left panel The Node details screen appears 2 In the Power Control section click On Off or Cycle or Graceful Shutdown to perform the corresponding power control...

Страница 46: ...rol screen 2 Click the Node Group drop down arrow and select the node group that you want to control power for from the list The Available list displays all interfaces in the selected node group 3 In...

Страница 47: ...Nodes for additional information on searching for nodes Figure 38 All Nodes List Favorite Nodes List You can create a personalized list of nodes you must access often in the Favorites list You can add...

Страница 48: ...odes list into the order in which you would like them to display in the Favorites list Select a node and then click the up and down arrows to move the nodes into the desired sequence Click Sort by Nam...

Страница 49: ...at specify how the nodes in certain Category and Element combinations display in the nodes lists CC SG also includes a Standard View which sorts the All Nodes list in alphabetical order You cannot cha...

Страница 50: ...pen the Edit View dialog 4 Type a new name for the custom view in the View Name field and then click OK Delete a custom view 1 Click the Custom View tab 2 Click the View Name drop down arrow and selec...

Страница 51: ...Click Open Chat beneath the Interface section The Chat dialog appears 3 Type your message in the bottom box and click Send 4 To end the chat session click Close Any participant can end a chat session...

Страница 52: ...l address currently associated with your CC SG User ID 1 Click the My Profile tab The My Profile screen opens 2 Type your new email address in the Email Address field and then click OK Set Default Nod...

Страница 53: ...46 COMMANDCENTER SECURE GATEWAY USER GUIDE...

Страница 54: ...default report view the next time you log in and run CC SG reports For all reports you can double click on a row to view further details of the report Note In all reports use CTRL click to deselect a...

Страница 55: ...d field you can see information if check box Login is enabled From Password Expiration you can see password expiration period in days 1 On the Reports menu click User Data The All Users Data report is...

Страница 56: ...APPENDIX A KEYBOARD SHORTCUTS 49 Appendix A Keyboard Shortcuts The following keyboard shortcuts can be used in the Director Client OPERATION KEYBOARD SHORTCUT Refresh F5 Print panel Ctrl P Help F1...

Страница 57: ...50 COMMANDCENTER SECURE GATEWAY USER GUIDE 255 80 3100...

Страница 58: ...Raritan Osaka 1 15 8 Nishihonmachi Nishi ku Osaka 550 0005 Japan Tel 81 6 4391 7752 Fax 81 6 4391 7761 Email sales raritan co jp Website Raritan co jp Asia Pacific Headquarters Raritan Taiwan 5F 121...

Отзывы: