9060 High Voltage Controller - Wiring Configurations
51
CP-13-05.3
WIRING CONFIGURATIONS
COMMON REMOTE CONFIGURATIONS
Remote Analog Voltage Control (Sourcing Configuration)
The following example configuration uses the following:
•
Sourcing Configured Digital Inputs (Apply 24VDC to activate the input)
•
Permanently Wired into Remote Mode (Jumper Wire from TB3-10 to TB3-2)
•
Normally Open (NO) Contact to Activate Reset when unit is Faulted
•
Normally Open (NO) Contact to Activate HV Trigger to turn on HV Cascade
•
0-10V Analog Voltage Control Signal
Figure 44: Remote Analog Voltage Control (Sourcing Configuration)
Содержание 80100 Series
Страница 2: ...CP 13 05 3...
Страница 5: ...CP 13 05 3...
Страница 11: ...9060 High Voltage Controller Safety CP 13 05 3 6 N O T E S...
Страница 27: ...9060 High Voltage Controller Installation CP 13 05 3 22 Figure 12 Controller Schematic...
Страница 51: ...9060 High Voltage Controller Maintenance CP 13 05 3 46 N O T E S...