9060 High Voltage Controller - Wiring Configurations
53
CP-13-05.3
Remote Tripleset Point Control (Sourcing Configuration)
The following example configuration uses the following:
•
Sourcing Configured Digital Inputs (Apply 24VDC to activate the input)
•
Normally Open (NO) Contact to Activate Reset when unit is Faulted
•
Normally Open (NO) Contact to Activate HV Trigger to turn on HV Cascade
•
Normally Open (NO) Contact to Activate remote mode. Turn off to move back to local mode to
allow preset values to be changed
•
Normally Open (NO) Contacts to Activate Setpoint 0 and Setpoint 1 to select the desired pre-
set value
Figure 46: Remote Tripleset Point Control (Sourcing Configuration)