11
STEP 3
( Locating Unit )
NOTE
The maximum recommended width between pads is 38”.
Consult the factory for applications that require installa-
tions wider than 38”.
1. Before selecting an installation site, check for proper
clearance and/or obstructions.
2. Remember that the lift moves rearward approximate-
ly 14” when raised. ( See Fig 3.1)
3. Always consult the building engineer before installing
this lift to make sure the floor is capable of sustaining the
load.
4. After selecting a site, place each unit in position
making sure that the hydraulic cylinders are placed
towards the inside. (See Fig 3.2)
5. It may be necessary to remove the tire rail adjacent
to the lift pad and overhang the edge of the rail to main-
tain the 36”- 38” recommended width between pads.
6. Each lift pad can overhang the edge of the pit a
maximum of two inches on each side as long as the
inside anchor bolt can be installed properly.
Fig. 3.1
Fig. 3.2.